F0689 F689: Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
G

Inadequate Supervision During Heat Therapy Resulted in a Burn

Monument Healthcare TaylorsvilleSalt Lake City, Utah Survey Completed on 02-03-2026

Summary

The facility failed to ensure that each resident received adequate supervision to prevent accidents when Resident 76 sustained a second-degree burn during heat therapy. Resident 76 was admitted and readmitted with diagnoses including anterior cord syndrome at C3 level of the cervical spinal cord, completed lesions at C4, C5, and C6, cognitive communication deficit, spastic hemiplegia, and paresthesia of the skin. On 2/2/26, the resident reported that hot water in the shower burned his arm, and he was observed with a wrap on the left forearm and two blisters on knuckles of the left hand. Record review showed the resident was sent to the hospital after staff found a rash with skin peeling to the left arm and large blisters on the left hand. The emergency department documented findings consistent with a second-degree burn isolated to the left forearm, with blistering on the left hand digits, and stated it appeared to be a burn rather than a medication reaction. The RNA stated he provided heat therapy using hot water and towels, did not test the water temperature with a thermometer that day, and placed hot wet towels on the resident's left forearm and hand. The DOR stated the facility did not have a hydrocollator, that warmed towels could not be heat regulated to prevent burns, and that Resident 76 had intermittent confusion. The restorative nursing program document did not include heat therapy recommendations, and the DON stated she thought there was a recommendation to provide heat therapy.

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0689 citations
Failure to Ensure Effective Fall Alarms and Supervision
E
F0689 F689: Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
Short Summary

Failure to ensure effective fall alarms and supervision: two residents had Smart Caregiver monitoring devices set to LOW volume, and one resident's bed alarm did not alert staff before the resident was found on the floor after an unwitnessed fall. One resident had dementia, osteoporosis, prior TIA, and cognitive impairment and was fully dependent on staff, while staff also found that a second resident's bed and recliner alarms did not activate properly during testing.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Assess Safety of Perimeter Mattresses
D
F0689 F689: Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
Short Summary

Failure to assess the safety of perimeter mattresses for two residents. Both residents had severely impaired cognition and significant mobility limitations, and both care plans included use of a perimeter mattress to define the edges of the bed. However, their Mobility, Physical Device, and Fall Risk assessments lacked documentation of a perimeter/defined edge mattress assessment. Staff interviews showed inconsistent understanding of the required order, IDT review, engineering review, and safety assessment before use.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Improper Mechanical Lift Transfers
D
F0689 F689: Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
Short Summary

Improper Mechanical Lift Transfers: A resident with dementia, spinal cord dysfunction, and dependence for transfers was supposed to be moved with a full-body mechanical lift and two staff members, but a TMA stated she transferred the resident alone. The resident reported that staff sometimes used only one person for lift transfers because of staffing shortages, while other staff and the DON stated this was unsafe and against policy.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Unsafe Wheelchair Fit and Incomplete Post-Fall Monitoring
D
F0689 F689: Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
Short Summary

Two residents were involved in accident-hazard deficiencies. One resident with cancer, PVD, and Alzheimer’s disease was observed in a wheelchair with feet extending past short footrests, with the lower legs resting against the hard footrests despite a care plan entry for padding. Another resident with dementia and a hx of falls had an unwitnessed fall, but ordered orthostatic BP monitoring was not completed accurately and staff reported no post-fall PT referral was received.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to assess electric wheelchair use and update fall interventions
G
F0689 F689: Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
Short Summary

A resident was given a new electric wheelchair without a prior therapy assessment and could not stop the chair, causing it to strike a bed frame and resulting in a leg laceration, tibia/fibula fractures, and a syncopal episode from blood loss. Another resident with cognitive impairment and high fall risk continued to self-transfer and fall, but the care plan was not updated with new fall interventions after repeated incidents.

Inspection fine: $17,665
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Unsafe One-Person Use of Mechanical Lift
E
F0689 F689: Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
Short Summary

A CNA used a Hoyer lift alone to weigh one resident, and another CNA was observed using a Hoyer lift alone to weigh a second resident. One resident’s care plan called for a 2-assist Hoyer lift, and the facility’s lift competency checklist and policy both required two caregivers for mechanical lift use; the DON and Director of Therapy also stated that two staff members are always required.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Citation search

Search every citation & Plan of Correction

Go to search
Citation watch

Track new serious citations across Utah

Get a heads-up on the newest immediate-jeopardy (J–L) citations in Utah — where surveyors are focused right now.

Free · about one email a month

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release July 29, 2026) and official state health department websites — never guesswork.

In your survey window? See what surveyors are citing.

The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.

Get the Survey-Prep Report
An unhandled error has occurred. Reload 🗙