F0641 F641: Ensure each resident receives an accurate assessment.
D

Incorrect MDS Medication Coding

Maple Winds Healthcare And Rehabilitation, LlcPortage, Pennsylvania Survey Completed on 05-18-2026

Summary

Accurate MDS assessments were not completed for three residents when medication items were not coded despite documented administration during the seven-day look-back period. The RAI User's Manual stated that Section N0415B1 was to be coded for antianxiety medications taken during the look-back period, Section N0415F1 for antibiotic medications taken during the look-back period, and Section N0415J1 for hypoglycemic medications taken during the look-back period. Resident 2 had physician orders for lorazepam 0.5 mg every morning and at bedtime for anxiety/restlessness, and the MAR showed the medication was given daily during the seven-day look-back period, but the quarterly MDS dated March 17, 2026 did not code Section N0145B for antianxiety medication. Resident 4 had an order for bacitracin ointment to be applied weekly to the nephrostomy tube exit wound, and the TAR showed it was given on April 3 and 10, 2026, but the annual MDS dated April 11, 2026 did not code Section N0401F1 for antibiotic medication. Resident 7 had orders for metformin 500 mg twice daily and linagliptin 5 mg every morning for diabetes, but the quarterly MDS dated February 24, 2026 did not code Section N0415J for hypoglycemic medication. The DON confirmed that the MDS assessments for Residents 2, 4, and 7 were coded incorrectly.

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0641 citations
Inaccurate MDS Assessments for Medication Use and Diagnoses
E
F0641 F641: Ensure each resident receives an accurate assessment.
Short Summary

A facility failed to ensure MDS assessments accurately reflected resident status for several residents. One resident’s admission MDS listed insulin injections even though she received liraglutide, while two other residents’ MDSs omitted antidepressant, opioid, and scheduled pain medication use despite active orders and MAR documentation. Another resident’s quarterly MDS failed to include respiratory failure as an active dx even though the record, orders, and resident interview confirmed the condition and oxygen use.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Inaccurate Resident Assessments
D
F0641 F641: Ensure each resident receives an accurate assessment.
Short Summary

Inaccurate resident assessments were identified for multiple residents when MDS coding did not match the clinical record, observations, or staff statements. One resident was coded as having a restraint-related chair device despite no restraints being observed or ordered, another was coded as not receiving antibiotics despite MAR documentation of mupirocin use, and two other residents had missing or incorrect MDS entries for diagnoses, ROM status, and skin/wound conditions based on admission records, physician notes, wound care documentation, and staff interviews.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Inaccurate MDS Coding for Weight Loss and Active Diagnoses
D
F0641 F641: Ensure each resident receives an accurate assessment.
Short Summary

Inaccurate MDS coding affected two residents. One resident had significant weight loss documented in the EHR, but the quarterly MDS did not reflect the loss as required. Another resident with lung cancer and metastatic disease had an admission MDS that omitted active cancer diagnoses from section I. The MDS/LPN acknowledged the missing diagnosis, and the DON stated MDS assessments were expected to be coded accurately.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Inaccurate MDS Assessments for Oxygen Use, Depression, and Range of Motion
D
F0641 F641: Ensure each resident receives an accurate assessment.
Short Summary

A facility failed to ensure MDS assessments accurately reflected resident status for multiple residents. One resident’s oxygen use was not captured in Section O despite PRN O2 orders and repeated oxygen saturation documentation, another resident’s MDS omitted oxygen use despite progress notes and an O2 order, a third resident’s MDS omitted depression despite a citalopram order, and a fourth resident’s MDS coded no ROM impairment even though PT identified quadriplegia with limitations in all extremities.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Inaccurate MDS Weight Loss Coding
D
F0641 F641: Ensure each resident receives an accurate assessment.
Short Summary

A resident’s quarterly MDS incorrectly coded significant weight loss even though his documented weights did not show 5% loss in 1 month or 10% loss in 6 months. The MDS RN said she based the coding on weight fluctuations and medication changes rather than actual loss during the look-back period, and the resident’s care plan continued to reflect significant unplanned weight loss, poor intake, and anxiety.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Inaccurate MDS Coding for Diabetes Medications
D
F0641 F641: Ensure each resident receives an accurate assessment.
Short Summary

Inaccurate MDS coding was found for two residents whose diabetes meds were non-insulin injectables. One resident with ESRD and diabetes had Ozempic ordered, and another resident with CKD and diabetes had Mounjaro ordered, but both MDS assessments incorrectly coded insulin use and hypoglycemic drug class use. The MDS coordinator acknowledged the coding error but did not update the assessments after learning of the inaccuracy.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Citation search

Search every citation & Plan of Correction

Go to search
Citation watch

Track new serious citations across Pennsylvania

Get a heads-up on the newest immediate-jeopardy (J–L) citations in Pennsylvania — where surveyors are focused right now.

Free · about one email a month

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release July 29, 2026) and official state health department websites — never guesswork.

In your survey window? See what surveyors are citing.

The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.

Get the Survey-Prep Report
An unhandled error has occurred. Reload 🗙