Respiratory Equipment and Therapy Orders Not Followed
Summary
Emergency respiratory equipment was not kept at the bedside for a resident with a tracheostomy. The resident had diagnoses including chronic respiratory failure with hypoxia and tracheostomy status, and the care plan and physician orders required a spare tracheostomy tube and obturator at the bedside, including one tube the same size and one size smaller. During observation, the extra tracheostomy tube, obturator, and smaller tube were not present at the bedside, and both an LPN and the ADON confirmed the supplies were missing and should have been there. Two residents were receiving oxygen without physician orders. One resident had diagnoses including COPD and lung cancer, was cognitively intact, and was observed wearing an oxygen nasal cannula connected to an oxygen concentrator running at four lpm even though the medical record contained no oxygen order. A second resident with diagnoses including neurogenic bladder and multiple cancers was also observed wearing an oxygen nasal cannula connected to an oxygen concentrator running at four lpm, while the record likewise had no order for oxygen administration. An LPN verified both residents were receiving oxygen, and the Administrator confirmed the absence of oxygen orders. BIPAP therapy was not initiated as ordered for a resident with COPD, and BIPAP equipment maintenance was not completed as required. The resident had physician orders for BIPAP settings, monthly tubing changes, and weekly cleaning of the mask and machine. During observation, the BIPAP machine was at the bedside, but the resident stated it had not been placed on her in approximately two months, the tubing was undated, no water was in the humidification chamber, and she reported the machine had not been cleaned or had parts changed in about two months and was missing parts. Staff interviews confirmed the BIPAP was not applied during the night because equipment was not available in the room, the tubing was undated, and the resident had not worn the BIPAP for two months. The machine usage report showed no use since 02/15/26 and a compliance summary of 44 of 90 days, or 48.9% application.
Penalty
Resources
Below are regulatory guidelines relevant to this citation:
Trusted data from CMS and state health departments
Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release July 29, 2026) and official state health department websites — never guesswork.
In your survey window? See what surveyors are citing.
The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.