Failure to Monitor Lift Slings and Stand Assist Devices
Summary
The facility failed to ensure routine monitoring was implemented for mechanical lift slings and stand assist devices. During observation of a mechanical lift transfer for a resident, staff used a sling that was worn and no longer had a tag attached. The CNA involved confirmed the sling was worn and missing its tag, and both CNAs stated they were not aware of who was responsible for monitoring sling integrity. Staff interviews also showed conflicting understanding of who monitored the slings, with CNA staff, laundry staff, the DON, and the Administrator each describing different responsibilities and no documentation available for sling integrity monitoring. Laundry staff stated the mechanical lift slings were washed separately from residents’ clothing and air dried on a clothesline, and two light blue slings observed in the laundry area were worn, discolored, and frayed. The laundry supervisor verified those slings were labeled as disposable. The medical records and inventory specialist stated disposable slings came from transport, the hospital, or EMS, and that CNAs were expected to monitor them before each use; the facility also had 26 brand new slings in the medical supply room. The DON stated laundry staff were responsible for monitoring sling integrity, but also verified there was no documentation of sling monitoring and was unaware the facility was using disposable slings. The facility also failed to ensure the Sara Steady stand assist devices were monitored. An incident log showed a resident fell when the left seat cushion broke off a Sara Steady while in use. Maintenance staff acknowledged welding a broken left seat bolt on one device, and the maintenance manager later confirmed two separate Sara Steady devices had issues with the left seat cushion bolt. He stated the third-party company inspected and serviced mechanical lifts but did not inspect the Sara Steady devices, and he had not inspected the other two devices until after the issue was discussed. The Administrator confirmed no one was assigned to inspect the Sara Steady devices, while the manufacturer’s manual required monthly checks of fasteners, seat assemblies, and casters.
Penalty
Resources
Below are regulatory guidelines relevant to this citation:
Trusted data from CMS and state health departments
Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release August 26, 2026) and official state health department websites — never guesswork.
In your survey window? See what surveyors are citing.
The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.