Incomplete Legionella and Waterborne Pathogen Prevention Program
Summary
Provide and implement an infection prevention and control program. The facility failed to establish and maintain a comprehensive, facility-specific infection prevention and control program designed to prevent the development and transmission of Legionella and other water-borne pathogens. Review of the water-borne pathogen prevention paperwork, last reviewed in October 2022 and removed from a binder labeled Disaster Plan, showed there was no facility-specific risk assessment using ASHRAE standard #188, the CDC toolkit assessment was incomplete with pages 6 through 36 missing, and there was no completed CDC Legionella Environmental Assessment Form. The paperwork also lacked a written explanation of water flow through the facility, identification of potential risk areas with assessments of each area’s risk level, a facility-specific outbreak plan for Legionella or other waterborne pathogens, testing protocols with acceptable control ranges, action plans for when control limits were not met, and documentation of a site log book with dated cleanings, sanitizing, descaling, and inspections. During the Life Safety Code walk-through, the water main supply was observed entering the basement of an older attached building and spreading through the laundry, a dry fire sprinkler system, former administrative offices, and then to the newer building addition. The surveyor observed at least two commercial clothes washers in the older building’s basement, numerous sinks and unused water pipes throughout the building, a complete wet fire sprinkler system in the newer building, public restrooms, housekeeping closets with mop/service sinks and eyewash stations, water boilers, hot water storage tanks, hot and cold running water piping throughout six resident room hallways, at least 55 resident rooms with private and/or shared bathrooms and sinks, a Beauty Shop with a sink, and at least three bathing rooms. In the kitchen, the surveyor observed a sanitizing three-sink area, a chemical low-heat dish-washing machine, a hand-washing sink, a steam table, and an ice machine in the adjacent service hallway. The Administrator stated there was not really anything for Legionella except what had been taken out of the disaster manual and that the documentation was old and outdated. The DOM stated he/she had no responsibilities regarding Legionella prevention practices and had no training on it.
Penalty
Resources
Below are regulatory guidelines relevant to this citation:
Trusted data from CMS and state health departments
Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release July 29, 2026) and official state health department websites — never guesswork.
In your survey window? See what surveyors are citing.
The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.