Bed Safety Checks Not Updated After Mattress Changes
Summary
The facility failed to complete a new assessment of the bed, side rails, and mattresses in active use for potential entrapment after the mattress was changed from the previously assessed mattress. The deficiency involved two residents with limited mobility who were using bilateral side rails, and the report states they were at risk for possible entrapment. The facility policy required adherence to manufacturer instructions and assessment of the space between the mattress and side rails to reduce entrapment risk, and the FDA guidance on bed entrapment zones was cited in the report. Resident #2 was admitted in February 2025 with a stage three pressure ulcer and had limited range of motion in the lower extremities and risk for pressure ulcers. Surveyors observed this resident in bed with bilateral side rails in use and an air mattress set to 150 lbs. on two separate occasions. The medical record did not contain an order for bilateral side rails or an air mattress. The facility’s Bed Safety Check documentation showed the Administrator had checked the bed on 2/12/25 and documented two half side rails with a standard mattress, not an air mattress. Resident #8 was admitted in February 2026 with a stage 1 pressure area, severe cognitive impairment, dependence on staff for all ADLs, and risk for pressure ulcers. Surveyors observed this resident in bed with bilateral side rails in use and an air mattress set to 240 lbs. on three occasions. The medical record included an order allowing bilateral side rails for turning and repositioning and a hospice nurse order for a low air loss mattress, which she said was placed on the bed when she visited the resident. However, the facility’s Bed Safety Check documentation showed the Administrator had checked the bed before admission and documented an air mattress, which did not match the hospice nurse’s account. During interview, the Administrator said the bed safety checks were inaccurate and stated that the mattresses and bedframes should have been assessed when the air mattresses were applied.
Penalty
Resources
Below are regulatory guidelines relevant to this citation:
Trusted data from CMS and state health departments
Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release October 8, 2026) and official state health department websites — never guesswork.
In your survey window? See what surveyors are citing.
The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.