F0880 F880: Provide and implement an infection prevention and control program.
D

Infection Control Failures During Wound Care and Contact Precautions

Sherrill HouseBoston, Massachusetts Survey Completed on 04-10-2026

Summary

The facility failed to establish and maintain an infection prevention and control program for one resident in the sample. Resident #4 was admitted with peripheral vascular disease, type 2 diabetes, and gangrene, and the MDS dated 3/27/26 indicated a BIMS score of 13 out of 15, with diabetic wounds and a pressure ulcer. Physician orders identified a gluteal cleft/coccyx pressure ulcer, wounds to left foot toes 1, 2, and 4, and a G-tube site wound. During a wound dressing observation, Nurse #5 sanitized his hands, donned a gown and gloves, and entered the room, but after removing gloves between wound care tasks he repeatedly put on new gloves without performing hand hygiene before continuing treatment to the G-tube site, left foot toes, and sacrum. The nurse later stated he should sanitize his hands every time he removed his gloves before applying a new pair, and the DON stated hand hygiene should be performed in between glove changes. The facility also failed to follow contact precautions for Resident #4. During an observation, CNA #1 entered the resident’s room wearing gloves but no gown and stated she thought a gown was only needed if emptying a Foley catheter and that she wore gloves because she was not giving direct care. During another observation, CNA #2 entered the contact precaution room wearing only a mask and no gloves or gown, then came out with a tray cover. CNA #2 stated she should have worn a gown and gloves before entering the room, and the DON stated staff should wear the right PPE before entering a precaution room.

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0880 citations
Failure to Follow EBP and Hand Hygiene During Incontinence Care
D
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

Failure to Follow EBP and Hand Hygiene During Incontinence Care: A resident with a catheter, hospice care, heart failure, and a lumbar compression fracture had a care plan for EBP requiring gown and gloves for high-contact care. During incontinence care, a CNA provided care without a gown, touched the bed linens, curtain, and gown with a uniform, and handled stool-soiled items without changing gloves or performing hand hygiene. A second CNA assisted with turning and wiping stool but changed gloves without hand hygiene; an RN later stated the PPE and hand hygiene used were not appropriate.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Infection Control and Enhanced Barrier Precautions Not Used During Wound Care
E
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

Infection Control and EBP Not Used During Wound Care Three residents with open wounds received wound care from RNs without PPE, and there was no PPE or precaution signage outside their rooms. The nurses and leadership stated the residents were not on EBP because the wounds were not infected or were considered simple dressings, even though the facility policy required gown and glove use for wound care involving any skin opening requiring a dressing and identified complex/infected wounds as EBP indications.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Follow EBP During Urinary Catheter Care
D
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

Failure to follow EBP during urinary catheter care: an LPN provided catheter care to a resident without wearing the required PPE gown, despite an EBP sign posted on the room door and gowns being available at the entrance. The nurse stated he wore a gown for contact precautions but not for EBP and was unaware a gown was required for catheter care; the IP, DON, and Administrator all stated a gown was expected for this high-contact activity.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Incomplete TB Testing on Admission
D
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

A resident admitted for skilled nursing services did not have documented TB testing completed on admission. A T-spot was later drawn, but there was no record that the specimen was sent to the lab or that results were obtained. The DON stated the facility missed the resident during TB audit checks and that the sample was not processed because the lab form was not sent with it, despite the facility policy requiring TB screening and testing within 72 hours of admission.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Infection Control Lapses With PEG Medication Administration and Oxygen Tubing Storage
D
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

The facility failed to maintain infection control for two residents. An RN did not sanitize hands between glove changes while administering medication via a resident’s PEG tube, despite the resident being on EBP and having a care plan for tube feeding and meds via PEG. In another instance, a resident with respiratory failure had oxygen tubing left unbagged when not in use, even though staff stated it should be bagged to prevent contamination.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Use PPE in Contact Isolation Room
D
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

A resident with klebsiella, a UTI, MDR organism status, an indwelling urinary catheter, and IV access was on contact precautions with signage at the door requiring hand hygiene, gown, and gloves before entry. A CNA entered the room and answered the call light without PPE, and later stated she only used PPE for catheter care. The charge nurse and DON stated staff were expected to wear PPE whenever entering the contact isolation room.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Citation search

Search every citation & Plan of Correction

Go to search
Citation watch

Track new serious citations across Massachusetts

Get a heads-up on the newest immediate-jeopardy (J–L) citations in Massachusetts — where surveyors are focused right now.

Free · about one email a month

Trusted data from CMS and state health departments