F0802 F802: Provide sufficient support personnel to safely and effectively carry out the functions of the food and nutrition service.
E

Dishwasher sanitation testing and documentation were not performed consistently

Good Samaritan - WaukonWaukon, Iowa Survey Completed on 04-30-2026

Summary

The facility failed to ensure staff were competent in procedures to test and document the hot water sanitation of the dishwasher. The facility had a new high temperature dishwasher installed, and the dishwasher placard required a wash temperature of 150 degrees Fahrenheit and a final rinse temperature of 180 degrees Fahrenheit. During observation, staff used a quat bucket test strip at first, then a digital thermometer placed on a dishrack inside the dishwasher, and later a different orange test strip. The digital thermometer readings during two additional cycles showed a maximum final temperature of 170.6 degrees Fahrenheit, which did not reach the required 180 degrees Fahrenheit, while the orange strip later turned orange to indicate 180 degrees Fahrenheit. Staff interviews showed confusion about how the dishwasher sanitation was supposed to be checked and documented. One staff member reported she had only recorded the temperatures shown on the dishwasher display and had never used the digital thermometer or orange test strips on the current dishwasher. Another staff member stated she had been using the digital thermometer daily but did not realize the testing needed to be documented. The Nutrition and Food Services Supervisor reported she used the digital thermometer daily, did not know the staff needed to document the testing, and did not have training records showing staff had been trained on the new dishwasher or on how to use the digital thermometer. She also stated there was no specific frequency for checking calibration of the digital thermometer. Review of the April 2026 Dish Machine Temperature Log showed staff were directed to document wash and final rinse temperatures morning, noon, and evening, but the log did not include direction or documentation showing that a digital thermometer check or sanitation test strip check had been completed. Vendor service reports documented wash and rinse temperatures on the dishwasher display, but did not document whether a digital thermometer had been used to verify sanitation. The dishwasher instruction manual required a hot water rinse temperature of 180 degrees Fahrenheit, and the facility policy directed staff to record the results of all completed tests on the appropriate form.

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0802 citations
Dish Machine Chlorine Test Strips Misread by Dietary Staff
D
F0802 F802: Provide sufficient support personnel to safely and effectively carry out the functions of the food and nutrition service.
Short Summary

Dish Machine Chlorine Test Strips Misread by Dietary Staff: Dietary staff were observed and interviewed while checking chlorine in the dish machine, and both DAs stated they estimated strip readings instead of interpreting the color chart correctly. The Dish Machine Temperature Log showed several recorded ppm values that did not match the chart, and the DS stated staff had been told to read the strips by estimating. The facility P&P required chlorine to read 50-100 ppm on the dish surface in the final rinse.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Food Service Staff Lacked Current Food Handler Certification
D
F0802 F802: Provide sufficient support personnel to safely and effectively carry out the functions of the food and nutrition service.
Short Summary

Food service staff lacked current food handler certification when two kitchen staff were observed preparing lunch meals and record review showed one expired certificate and one missing certificate. Interviews confirmed one staff member did not have a current certificate and another learned her certificate had expired, while the MTD was assisting in the kitchen after the prior dietary manager was terminated.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Dishwasher Sanitization Temperatures Not Understood by Kitchen Staff
F
F0802 F802: Provide sufficient support personnel to safely and effectively carry out the functions of the food and nutrition service.
Short Summary

Dishwasher Sanitization Temperatures Not Understood by Kitchen Staff: Kitchen staff did not know the required high-temp dishmachine settings for sanitization. During observation, the wash cycle reached 150°F and the rinse cycle reached 171°F, while the staff member operating the machine stated those were normal and sufficient to sanitize dishes. The DM and RD later stated the wash cycle needed to reach 160°F and the rinse cycle at least 180°F, and the facility policy listed the same temperatures.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Expired Food Handler Certificate for Dietary Aide
D
F0802 F802: Provide sufficient support personnel to safely and effectively carry out the functions of the food and nutrition service.
Short Summary

Expired Food Handler Certificate for Dietary Aide: The facility failed to ensure a dietary aide maintained a current Food Handler Certificate. Record review showed the aide’s certificate had expired, and interviews with the DM, DON, and Administrator confirmed they were responsible for tracking staff certification status but had not noticed the expiration. The aide stated she did not realize the certificate had expired, and the facility policy required all employees who handle, prepare, or serve food to be trained in safe food handling and preventing foodborne illness.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Dietary staffing shortages led to repeated dining room closures and service issues
F
F0802 F802: Provide sufficient support personnel to safely and effectively carry out the functions of the food and nutrition service.
Short Summary

Repeated dietary staffing shortages resulted in frequent dining room closures, missed meal service in the dining room, and resident complaints about food quality, incorrect menus, and the kitchen running out of items. Staff reported that cooks and dietary aides repeatedly called off or were not scheduled, several dietary workers were not replaced, and the Administrator said staffing decisions were made by a third-party vendor.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Insufficient Dietary Staffing Caused Delayed Meal Service
E
F0802 F802: Provide sufficient support personnel to safely and effectively carry out the functions of the food and nutrition service.
Short Summary

Insufficient dietary staffing delayed meal service and disrupted resident care. Dietary staff were still on the tray line during breakfast service, the last breakfast cart left the kitchen late, and lunch tray line preparation was repeatedly delayed with trays not ready until well after the scheduled time. Residents on the unit were still eating breakfast late in the morning, lunch trays were not delivered to the 400 hall until mid-afternoon, and CNAs reported meals were often so late that it affected when they could provide showers and other care.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Citation search

Search every citation & Plan of Correction

Go to search
Citation watch

Track new serious citations across Iowa

Get a heads-up on the newest immediate-jeopardy (J–L) citations in Iowa — where surveyors are focused right now.

Free · about one email a month

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release July 29, 2026) and official state health department websites — never guesswork.

In your survey window? See what surveyors are citing.

The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.

Get the Survey-Prep Report
An unhandled error has occurred. Reload 🗙