F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
D

Incomplete Labeling of Tube Feeding Formula and Flush Containers

Pruitthealth - PeakeMacon, Georgia Survey Completed on 05-03-2026

Summary

The facility failed to properly label the nutritional formula and flush containers for two residents who received nutrition through gastrostomy tubes. R139 was admitted with diagnoses including dysphagia and esophagitis, and had a physician order for Jevity 1.5 at 40 mL/hour overnight from 8:00 PM to 6:00 AM. The care plan identified tube feeding for aspiration risk and directed that tube feeding be given as ordered. Observations on 05/01/2026 and 05/02/2026 showed that R139’s formula and flush container labels were missing the dates and times of administration initiation. R88 was admitted with diagnoses of dysphagia, oropharyngeal phase, and gastroparesis. Her annual MDS documented tube feeding, and physician orders included Osmolite 1.2 by G-tube at 65 mL/hour for 16 hours and a tube flush order for 60 mL/hour for 16 hours. Her care plan stated she was at risk for altered nutrition and dehydration, had a feeding tube related to dysphagia, and was strictly NPO. Observations on 05/01/2026 showed that R88’s formula and flush containers were not labeled or dated with the administration initiation date and time. During interview, an LPN stated the labels should include the resident name, room number, written time, and date administered, and confirmed the labels for R139 and R88 were incomplete. The DHS stated tube-feeding formula and flush containers should be labeled with the date and time they were hung and the nurse’s initials.

Penalty

1 days payment denial
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0693 citations
Incorrect Enteral Feeding Rate
D
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

A resident with a feeding tube, severe cognitive impairment, quadriplegia, and persistent vegetative state was observed receiving g-tube feeding at 55 mL/hr even though the physician order specified Isosource 1.5 at 85 mL/hr for 22 hours. An LVN confirmed the incorrect pump rate and stated he was unsure why it was set that way, while the DON and ADM stated staff were expected to verify orders and pump settings and that nursing was responsible for tube feeding administration.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Feeding Tube Left Infusing While Resident Was Flat During Care
D
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

A resident with a G-tube, CVA, dysphagia, and severe cognitive impairment was observed receiving incontinent care with the HOB flattened while tube feeding continued to infuse. Two CNAs did not call the nurse to stop the pump before care, and the resident remained flat for 36 minutes while appearing uncomfortable. Interviews confirmed staff knew the pump should be stopped and that only nurses handle the tube and pump.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Tube Feeding Administration and Documentation Deficiencies
D
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

Two residents with feeding tubes had enteral nutrition documented inconsistently with provider orders. For one resident, staff recorded pump on/off times but not the total amount infused; for another resident, nurses only initialed shifts without documenting actual start/stop times or fluid amounts. An LPN, resident care manager, and DON acknowledged the documentation did not meet expectations.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Tube Feeding Formula and Flush Bag Not Dated or Labeled
D
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

A resident with severe cognitive impairment and tube feeding orders had formula and a water flush bag that were not dated or labeled. The care plan addressed tube feeding, aspiration monitoring, and keeping the HOB elevated, and an RN stated she checks placement, primes the pump, and verifies the formula is not expired, labeled, and dated. Facility policy required checking the enteral nutrition label against the order, including the resident name, formula type, preparation date and time, and rate of administration.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Verify GT Placement and Residual Before Medication Administration
D
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

An LVN failed to verify GT placement and check GRV before administering medications to a resident with dysphagia, a GT, and severely impaired cognitive skills. The resident’s orders required GT placement/patency checks and residual checks every shift, and the facility policy required tube placement verification and residual checks before medication administration.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Improper Head-of-Bed Positioning During GT Feeding
D
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

Improper Head-of-Bed Positioning During GT Feeding: A resident receiving GT feeding was observed lying in bed with the HOB at 20 degrees while the feeding was actively infusing, despite the care plan and facility P&P directing HOB elevation to 30 to 45 degrees or upright positioning during and after tube feeding. An LVN confirmed the resident should have been at 45 degrees and verified the lower HOB setting during the feeding; the Administrator and DON acknowledged the findings.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Citation search

Search every citation & Plan of Correction

Go to search
Citation watch

Track new serious citations across Georgia

Get a heads-up on the newest immediate-jeopardy (J–L) citations in Georgia — where surveyors are focused right now.

Free · about one email a month

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release July 29, 2026) and official state health department websites — never guesswork.

In your survey window? See what surveyors are citing.

The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.

Get the Survey-Prep Report
An unhandled error has occurred. Reload 🗙