Resident Sink Water Temperatures Exceeded Safe Limits
Summary
The facility failed to ensure resident-accessible water temperatures were maintained at safe and comfortable levels and did not exceed the required range of 105 to 115 degrees Fahrenheit in two units, affecting resident room bathrooms in rooms 204, 315, and 113. During the initial tour, water flow temperatures in resident bathroom sinks were observed to be too hot to hold the back of the hand under the water. The surveyor and Director of Maintenance later tested multiple resident room sinks and found temperatures of 121 degrees Fahrenheit in room 204, 121 degrees Fahrenheit in room 315, and 124 degrees Fahrenheit in room 113. The Director of Maintenance stated he had been in the role for four months and did not have an audit plan for testing water temperatures at individual resident room sinks. He said he set the facility water heaters at around 110 to 115 degrees Fahrenheit and was not sure how many water heaters were in the building. He confirmed there were at least three water heaters for resident rooms and shower rooms, plus a separate booster for the kitchen and laundry room, but he did not know the settings for those units. He also confirmed he had no documented evidence of testing hot water temperatures in resident rooms and did not know that was required. During the tour, the Director of Maintenance used a digital infrared thermometer to test the water and stated he did not need to calibrate it. The facility policy provided later required daily hot water checks using a calibrated dial stem thermometer, with resident rooms, shower rooms, and common areas kept below state requirements. The Director of Maintenance later remembered another bank of water heaters in a locked courtyard area that supplied resident spaces, including community shower rooms and resident room bathroom sinks; that heater was reading 127 degrees Fahrenheit and had no temperature log. The Nursing Home Administrator stated the facility had plumbing issues and needed parts to regulate the temperature in one of the water heaters, and confirmed there were no work orders available before the surveyor identified the errant temperatures.
Penalty
Resources
Below are regulatory guidelines relevant to this citation:
Trusted data from CMS and state health departments
Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release August 26, 2026) and official state health department websites — never guesswork.
In your survey window? See what surveyors are citing.
The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.