Unsafe and Unclean Facility Environment
Summary
The facility failed to maintain a clean, comfortable, and homelike environment for residents. During a tour, five ceiling tiles were observed bowing in one room, with warped and peeling paint above a wall-mounted air-conditioning unit. In the hallways near multiple rooms, AC vents were actively dripping condensation onto the floors while maintenance staff replaced ceiling tiles. Dust was also observed in vents in the main conference room and hallways, and a leak was noted in the common television area with water seeping through ceiling tiles and light fixtures. The Maintenance Director stated he was aware of ongoing condensation and AC issues throughout the building and was the only maintenance staff member for the facility. Review of the maintenance work-order log showed long-standing unresolved HVAC problems, including a rooftop AC unit on the 600 hall out of operation since 06/25/2024, an AC unit in the common area out of operation since 04/28/2025, lack of proper cooling in the laundry room since 06/12/2025, a rooftop unit in the rehabilitation gym out of operation since 11/10/2025, and a rooftop hallway AC unit in the 1000 area out of operation since 12/12/2025. Additional recent issues included an AC electrical problem and nine work orders related to ceiling tiles. The Administrator and Regional President stated they were aware of the ongoing AC issues and had correspondence requesting funding for repairs. The facility also had multiple rooms and bathrooms with unsanitary and poorly maintained conditions. Observations included unlabeled wash basins on the bathroom floor, one containing a urine-collecting toilet insert, dried brownish fluid on the wall, an uncovered toothbrush and uncapped toothpaste in a water pitcher, and other personal care items left unlabeled. In other rooms, surveyors observed stained bathroom flooring, cracked walls and flooring, rusted toilets and pipes, dirty tubs with used washcloths, broken furniture, clutter, debris, hanging lights, and brownish discoloration on ceiling tiles. A foul sewage-like odor was noted in the hallways and conference room throughout the survey, and staff interviews linked the odor to possible pipe leaks. The Environmental Services Manager and Maintenance Director both acknowledged ongoing leaks and other building issues, including leaks around AC returns and possible pipe-related odor, without identifying a repair plan during the interviews.
Penalty
Resources
Below are regulatory guidelines relevant to this citation:
Trusted data from CMS and state health departments
Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release August 26, 2026) and official state health department websites — never guesswork.
In your survey window? See what surveyors are citing.
The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.