Failure to Order and Implement Ordered Monitoring and Fluid Restriction
Summary
Resident 109, who was admitted with type 2 DM, unspecified protein-calorie malnutrition, HF, CKD, weakness, and HTN, was receiving Humalog and Lantus and had care plan interventions for blood glucose checks and insulin administration as ordered. During observation, the resident was using a personal CGM on the left upper arm/shoulder area and stated that facility staff were not checking her blood glucose with the facility glucometer, but instead were relying on readings from her personal monitor. She also stated that her friend changed the sensor about every two weeks and that she could not recall anyone from the facility checking the device since admission. During record review and interview, an LPN confirmed that the resident’s blood glucose readings documented on the e-MAR were obtained from the resident’s personal monitor and that insulin was administered based on those readings. The LPN also confirmed there were no physician orders, facility procedures, or documentation regarding quality control checks, verification of accuracy, calibration, or sensor changes for the resident-owned glucose monitoring device. The DON stated the facility expected nurses to notify the physician and obtain an order for use of a personal CGM, and to follow manufacturer guidelines for operation, accuracy verification, calibration, quality control, and supervision of sensor changes, but no such order or documentation was present for this resident. Resident 4, who was admitted with RSV bronchiolitis, pneumonia, acute and chronic respiratory failure, acute pulmonary edema, COPD with acute exacerbation, HF, acute kidney failure, and CKD, was seen after rehospitalization for acute HFpEF and hematemesis. The physician’s history and physical documented that the resident was off furosemide and that a fluid restriction would be written. However, review of the current order summary showed no physician order for fluid restriction, and review of the nurses’ progress notes found no documentation that the fluid restriction had been addressed, clarified, implemented, or monitored. An LPN confirmed the physician had included fluid restriction in the treatment plan, but it was not present in the active orders.
Penalty
Resources
Below are regulatory guidelines relevant to this citation:
Trusted data from CMS and state health departments
Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release October 8, 2026) and official state health department websites — never guesswork.
In your survey window? See what surveyors are citing.
The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.