F0689 F689: Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
K

Failure to Maintain Safe Bed Systems and Prevent Accidents

Avantara WatertownWatertown, South Dakota Survey Completed on 04-29-2026

Summary

The deficiency involves the facility’s failure to ensure a safe bed environment free from entrapment hazards and to provide adequate supervision and accident prevention for multiple residents. Surveyors observed that several residents had loose side rails or grab bars and mattresses that were not secured or properly fitted, creating gaps between the rails, mattress, and bedframe. One resident’s bilateral side rails could move away from the bed one to two inches, and there was a five‑inch gap between the top of his mattress and the headboard. Another resident, who was legally blind and had previously fallen out of bed during a dream and sustained a brain bleed, had a left side rail that could move three inches away from the mattress; he reported telling a CNA and his daughter about the loose rail about a week earlier. A third resident used bilateral side rails for bed mobility; her right rail could move two to three inches away from the bed, the openings within the rails measured three and one‑half inches wide by 13 inches high, and there was a seven‑inch gap between the foot of her mattress and the footboard. Surveyors also found that the facility’s entrapment assessments and maintenance audits were incomplete or inaccurately documented. Review of the maintenance logbook for side rail inspections from January through April showed that only zone 1 (the opening within the side rail) was consistently assessed, while the other six FDA‑defined entrapment zones were often marked as not applicable, including zone 7 (the space between the mattress and headboard or footboard) even for residents without bed rails. In some months, all seven zones were documented as not applicable for numerous residents known to have side rails, and some residents with side rails were not included in the audits at all. The DON was unsure if there was a specific entrapment assessment policy and believed maintenance handled these assessments, while also acknowledging missing documentation for side rail assessments, consents, and physician orders, and that some side rails were installed without proper documentation. Additional deficiencies related to accident prevention and supervision were identified in several facility‑reported incidents. One resident with a history of stroke and left‑sided weakness fell from his bed while trying to remove his socks after a CNA left his bed at waist height; his care plan at that time did not specify a required bed height, and he was later diagnosed with a minor closed head injury and abrasions. Another resident, care planned to require two staff for transfers and use of a sit‑to‑stand lift, was transferred by a single contracted CNA using a sling that was too small and the wrong hook, causing back pain; the resident and his family reported that he was often transferred by only one staff member despite the care plan. A cognitively impaired resident at risk for elopement exited through a door whose alarm had been deactivated during daytime hours so visitors could enter and exit, walked outside in very cold weather, and re‑entered through another door after about 15 minutes. A further resident, on anticoagulant therapy, fell while transferring herself to the bathroom and hit her head; she had fallen 11 times in 30 days, and the provider failed to implement, review, and revise interventions to reduce her fall risk. These events collectively demonstrate failures to follow care plans, maintain environmental safety devices such as alarms and bed systems, and provide adequate supervision to prevent accidents. The surveyors determined that these failures, particularly the unsecured side rails and unassessed mattress gaps, created a risk for entrapment injury or harm and issued an Immediate Jeopardy finding under F689 related to accident hazards and supervision. Observations throughout the building confirmed multiple safety concerns with side rail installation, maintenance, and bed zone assessments, including loose rails and significant gaps between mattresses and headboards or footboards. Facility leadership and maintenance staff acknowledged that gaps between mattresses and bed ends and loose side rails posed a risk for entrapment and injury, and that entrapment zone measurements and assessments had not been consistently completed according to FDA guidance and facility policy.

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0689 citations
Failure to Ensure Effective Fall Alarms and Supervision
E
F0689 F689: Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
Short Summary

Failure to ensure effective fall alarms and supervision: two residents had Smart Caregiver monitoring devices set to LOW volume, and one resident's bed alarm did not alert staff before the resident was found on the floor after an unwitnessed fall. One resident had dementia, osteoporosis, prior TIA, and cognitive impairment and was fully dependent on staff, while staff also found that a second resident's bed and recliner alarms did not activate properly during testing.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Assess Safety of Perimeter Mattresses
D
F0689 F689: Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
Short Summary

Failure to assess the safety of perimeter mattresses for two residents. Both residents had severely impaired cognition and significant mobility limitations, and both care plans included use of a perimeter mattress to define the edges of the bed. However, their Mobility, Physical Device, and Fall Risk assessments lacked documentation of a perimeter/defined edge mattress assessment. Staff interviews showed inconsistent understanding of the required order, IDT review, engineering review, and safety assessment before use.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Improper Mechanical Lift Transfers
D
F0689 F689: Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
Short Summary

Improper Mechanical Lift Transfers: A resident with dementia, spinal cord dysfunction, and dependence for transfers was supposed to be moved with a full-body mechanical lift and two staff members, but a TMA stated she transferred the resident alone. The resident reported that staff sometimes used only one person for lift transfers because of staffing shortages, while other staff and the DON stated this was unsafe and against policy.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Unsafe Wheelchair Fit and Incomplete Post-Fall Monitoring
D
F0689 F689: Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
Short Summary

Two residents were involved in accident-hazard deficiencies. One resident with cancer, PVD, and Alzheimer’s disease was observed in a wheelchair with feet extending past short footrests, with the lower legs resting against the hard footrests despite a care plan entry for padding. Another resident with dementia and a hx of falls had an unwitnessed fall, but ordered orthostatic BP monitoring was not completed accurately and staff reported no post-fall PT referral was received.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to assess electric wheelchair use and update fall interventions
G
F0689 F689: Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
Short Summary

A resident was given a new electric wheelchair without a prior therapy assessment and could not stop the chair, causing it to strike a bed frame and resulting in a leg laceration, tibia/fibula fractures, and a syncopal episode from blood loss. Another resident with cognitive impairment and high fall risk continued to self-transfer and fall, but the care plan was not updated with new fall interventions after repeated incidents.

Inspection fine: $17,665
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Unsafe One-Person Use of Mechanical Lift
E
F0689 F689: Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
Short Summary

A CNA used a Hoyer lift alone to weigh one resident, and another CNA was observed using a Hoyer lift alone to weigh a second resident. One resident’s care plan called for a 2-assist Hoyer lift, and the facility’s lift competency checklist and policy both required two caregivers for mechanical lift use; the DON and Director of Therapy also stated that two staff members are always required.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Citation search

Search every citation & Plan of Correction

Go to search
Citation watch

Track new serious citations across South Dakota

Get a heads-up on the newest immediate-jeopardy (J–L) citations in South Dakota — where surveyors are focused right now.

Free · about one email a month

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release July 29, 2026) and official state health department websites — never guesswork.

In your survey window? See what surveyors are citing.

The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.

Get the Survey-Prep Report
An unhandled error has occurred. Reload 🗙