F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
D

Unlabeled Enteral Nutrition and Water Bags Used for Tube Feedings

Laurels Of West Columbus, TheColumbus, Ohio Survey Completed on 04-13-2026

Summary

The deficiency involves the facility’s failure to ensure enteral nutrition and water bags used for tube feeding were properly labeled and dated for two residents with active tube feeding orders. For one resident with diagnoses including type 2 diabetes mellitus, adult failure to thrive, mild protein-calorie malnutrition, and gastrostomy status, orders specified NPO status with Osmolite 1.2 at 100 mL/hr for 14 hours starting in the evening and water flushes at 40 mL/hr, along with enhanced barrier precautions related to enteral feedings. Surveyors observed two full bags, one containing enteral nutrition and one containing water, hanging at the bedside with lines attached but not yet connected to the resident. The formula was not in its original packaging but had been poured into an unlabeled plastic feeding bag. Neither the formula bag nor the water bag had any labeling to indicate the date or time of preparation, the type of formula, or the ordered rate. An LPN then entered the room, flushed the gastrostomy tube, connected the unlabeled bags to the resident, and started the feeding pump without adding any labels, and then left the room while the feeding was running, confirming in interview that both bags should have been labeled with date and time and acknowledging they were not. For a second resident with diagnoses including hemiplegia and hemiparesis following stroke, dysphagia following stroke, unspecified protein-calorie malnutrition, and gastrostomy, physician orders included continuous Glucerna 1.5 at 55 mL/hr with 50 cc water flushes every hour. The record also contained an order to change the tube feeding bag and tubing every night shift and to label new bags and bottles, including water, with name, date, time, and amount per hour. Surveyors observed at the bedside that the water bag hung next to the enteral nutrition bag was actively running to flush the tube feeding line but was not labeled with the date and time of preparation, although the enteral nutrition bag was labeled. In interview, an RN verified that the water bag was unlabeled, stated that water is usually prepared at the same time as the formula, and acknowledged that each individual bag should be labeled with date and time of preparation. These observations showed that the facility did not follow its own orders and labeling requirements for tube feeding products and water for both residents.

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0693 citations
Incomplete Enteral Feeding Order for Resident with G-Tube
D
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

A resident with a g-tube, dysphagia, and malnutrition had an enteral feeding order that omitted the formula strength and the administration method. The chart showed the resident was receiving Isosource 1.5 cal bolus feedings, but the active order only stated enteral feed via g-tube. The MDS Coordinator, LVN, and DON all acknowledged the order was incomplete, and the facility policy required enteral nutrition orders to include the product and administration method.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Verify GT Placement Before Medication Administration
D
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

A resident with a GT, GERD, interstitial pulmonary disease, and dementia was observed receiving medications via the GT without the nurse confirming tube placement. The LVN stated she did not check GRV before administering the medications, and the RN and DON stated GT placement and residuals should be checked prior to medication administration, although the facility policy did not include GRV checking.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Inadequate G-tube care and enteral feeding documentation
E
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

Inadequate G-tube care and enteral feeding documentation. A resident with CVA-related hemiplegia and dysphagia had orders for NPO status, continuous Jevity 1.5 via G-tube, water flushes, residual checks every shift, and oral care, but the record lacked an order for tube placement verification or shift site care. MAR/TAR review showed no consistent documentation of G-tube site care or residual checks, water flushes were not always documented as ordered, and feeding amounts were recorded in two places with inconsistent entries; nursing notes were also not present for every shift.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Delayed G-tube Feeding Administration
D
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

A resident with a g-tube, severe cognitive impairment, and dependence on staff for all nutrition and hydration did not receive continuous tube feeding at the ordered start time. The feeding pump was observed off while the resident was away from his room and remained off after he returned from the Day Center; an LVN later connected the feeding after changing the g-tube dressing. Staff stated the resident often returned after the ordered start time and was therefore not hooked up as ordered.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Resident with G-tube was fed while lying flat
D
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

A resident with a G-tube was observed lying supine and below 30 degrees while enteral feeding was running. A CNA said the resident was lower than she should have been during the feeding and that the tube feeding should be turned off when repositioning is needed. An LVN later confirmed the resident should not be lying flat during feeding, paused the tube feeding, and said the resident needed assistance to be safely elevated; the DON stated the head should be elevated above 30 to 45 degrees and never flat during feeding.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Verify G-Tube Placement Before Medications and Water Administration
D
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

Failure to Verify G-Tube Placement Before Medications and Water Administration: An LPN administered crushed meds and water through a resident’s PEG tube without routinely checking tube placement first. The resident had dysphagia, cognitive impairment, and received most calories and fluids via the feeding tube. The RN and DON also indicated uncertainty about whether placement checks were still required, and no provider order exempting the resident from placement verification was found, despite the facility policy requiring placement checks before tube feedings and meds.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Citation search

Search every citation & Plan of Correction

Go to search
Citation watch

Track new serious citations across Ohio

Get a heads-up on the newest immediate-jeopardy (J–L) citations in Ohio — where surveyors are focused right now.

Free · about one email a month

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release August 26, 2026) and official state health department websites — never guesswork.

In your survey window? See what surveyors are citing.

The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.

Get the Survey-Prep Report
An unhandled error has occurred. Reload 🗙

Connection lost — reconnecting… We couldn't reconnect automatically. Please reload the page to continue.