F0689 F689: Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
D

Unsafe Hallway Mopping Created Wet-Floor Hazard

Pinehurst Healthcare & Rehabilitation CenterPinehurst, North Carolina Survey Completed on 04-30-2026

Summary

The deficiency involves a failure to maintain a safe environment free from accident hazards in the 300 hallway, specifically the lower end serving rooms 304 through 312. During a continuous observation, a housekeeper was seen mopping the entire length and width of an approximately 4-foot by 10-foot section of the hallway floor, leaving the entire area completely wet across the hall. A wet floor sign was placed only at the end of the hallway near one room, while the mopping practice required residents, staff, and visitors to walk on the wet floor if they needed to pass through that section. In an interview, the housekeeper stated she usually mopped across the entire floor and then followed with a dry mop, and believed that placing a wet floor sign at the end of the hallway was sufficient to warn others. She acknowledged she should have left a dry area for others to walk on. The Director of Housekeeping confirmed that the housekeeper should have mopped only one side of the hallway to leave a dry path and that a caution sign should have been placed at the end of the wet area to direct others to use the dry side. The floor technician explained that he normally cleans hallways with a machine that scrubs and dries the floor, working on one half of the floor at a time to keep a dry walking path, and that housekeeping would only mop for minor spills. The DON also stated the housekeeper should have left a dry, clear path and only mopped one half of the hallway at a time.

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0689 citations
Failure to Ensure Effective Fall Alarms and Supervision
E
F0689 F689: Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
Short Summary

Failure to ensure effective fall alarms and supervision: two residents had Smart Caregiver monitoring devices set to LOW volume, and one resident's bed alarm did not alert staff before the resident was found on the floor after an unwitnessed fall. One resident had dementia, osteoporosis, prior TIA, and cognitive impairment and was fully dependent on staff, while staff also found that a second resident's bed and recliner alarms did not activate properly during testing.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Assess Safety of Perimeter Mattresses
D
F0689 F689: Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
Short Summary

Failure to assess the safety of perimeter mattresses for two residents. Both residents had severely impaired cognition and significant mobility limitations, and both care plans included use of a perimeter mattress to define the edges of the bed. However, their Mobility, Physical Device, and Fall Risk assessments lacked documentation of a perimeter/defined edge mattress assessment. Staff interviews showed inconsistent understanding of the required order, IDT review, engineering review, and safety assessment before use.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Improper Mechanical Lift Transfers
D
F0689 F689: Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
Short Summary

Improper Mechanical Lift Transfers: A resident with dementia, spinal cord dysfunction, and dependence for transfers was supposed to be moved with a full-body mechanical lift and two staff members, but a TMA stated she transferred the resident alone. The resident reported that staff sometimes used only one person for lift transfers because of staffing shortages, while other staff and the DON stated this was unsafe and against policy.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Unsafe Wheelchair Fit and Incomplete Post-Fall Monitoring
D
F0689 F689: Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
Short Summary

Two residents were involved in accident-hazard deficiencies. One resident with cancer, PVD, and Alzheimer’s disease was observed in a wheelchair with feet extending past short footrests, with the lower legs resting against the hard footrests despite a care plan entry for padding. Another resident with dementia and a hx of falls had an unwitnessed fall, but ordered orthostatic BP monitoring was not completed accurately and staff reported no post-fall PT referral was received.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to assess electric wheelchair use and update fall interventions
G
F0689 F689: Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
Short Summary

A resident was given a new electric wheelchair without a prior therapy assessment and could not stop the chair, causing it to strike a bed frame and resulting in a leg laceration, tibia/fibula fractures, and a syncopal episode from blood loss. Another resident with cognitive impairment and high fall risk continued to self-transfer and fall, but the care plan was not updated with new fall interventions after repeated incidents.

Inspection fine: $17,665
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Unsafe One-Person Use of Mechanical Lift
E
F0689 F689: Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
Short Summary

A CNA used a Hoyer lift alone to weigh one resident, and another CNA was observed using a Hoyer lift alone to weigh a second resident. One resident’s care plan called for a 2-assist Hoyer lift, and the facility’s lift competency checklist and policy both required two caregivers for mechanical lift use; the DON and Director of Therapy also stated that two staff members are always required.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Citation search

Search every citation & Plan of Correction

Go to search
Citation watch

Track new serious citations across North Carolina

Get a heads-up on the newest immediate-jeopardy (J–L) citations in North Carolina — where surveyors are focused right now.

Free · about one email a month

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release July 29, 2026) and official state health department websites — never guesswork.

In your survey window? See what surveyors are citing.

The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.

Get the Survey-Prep Report
An unhandled error has occurred. Reload 🗙