Unsafe and Poorly Maintained Resident Areas
Summary
The facility did not maintain a clean, comfortable, and homelike environment in the Forest Unit and Town Hall Common area. During observation, resident rooms had leaking radiator units, with wet towels or sheets placed on the floor in front of the radiators to absorb water. One resident room also had a missing baseboard between the wall and radiator. The Forest Unit hallways and common areas had torn or missing wallpaper, scuffed walls and doors, and rust stains on ceiling trim. The Forest Unit shower room also had low water pressure, and the shower hot water temperature was measured at a highest recorded temperature of 91.9 degrees Fahrenheit during the observation period. Resident Council members reported ongoing concerns about low water pressure on units and hot water taking an extended time to reach a comfortable temperature. They stated these concerns had been discussed in monthly meetings and reported to CNAs, and that maintenance staff had responded at times, but the problems returned. They also stated that the mixers added to the shower rooms a few years earlier made the pressure and hot water concerns worse, and that hot water delays caused cares to be rushed. In addition, residents reported that lighting in the Town Hall Common area was not sufficient during activities and that non-functioning fluorescent lights made it difficult to read bingo cards and documents. The Plant Operations Manager stated the radiators were leaking due to condensation and that drip pans could become clogged, causing leakage to the floor. They stated they were not aware of the leaking radiators in the affected rooms and did not recall receiving maintenance requisitions for them. They also stated there was no set schedule for radiator maintenance and that the maintenance department relied on unit staff to report concerns. For the Town Hall Common area, approximately 25% of the fluorescent ceiling lights were not functioning, and the Plant Operations Manager stated they had not contacted a contractor to replace them and were not aware of any recent replacement of non-functioning bulbs. The manager also stated they were not aware of the Resident Council concerns about weak water pressure and delayed hot water in the building.
Penalty
Resources
Below are regulatory guidelines relevant to this citation:
Trusted data from CMS and state health departments
Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release August 26, 2026) and official state health department websites — never guesswork.
In your survey window? See what surveyors are citing.
The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.