Widespread Environmental Disrepair and Unsafe Conditions Throughout Facility
Summary
The facility failed to provide a functional, safe, clean, and comfortable environment for residents, staff, and the public, affecting all 71 residents in the building. The Maintenance Director job description required planning, organizing, and directing maintenance operations, repairing facility and resident property, coordinating outside vendors when needed, maintaining supplies and equipment for a safe environment, promptly reporting damage to the Administrator, and conducting weekly inspections to ensure quality control. Despite these requirements, the former Maintenance Director was terminated for incompetence, substandard productivity, and unsatisfactory job performance, including failure to complete tasks related to facility environment issues identified during a health survey. Additionally, the Administrator in Training was unable to provide maintenance work orders for a period of over six weeks, indicating a lack of documented maintenance follow-through. Surveyor observations throughout multiple halls and rooms showed widespread physical plant deterioration and unsafe conditions. These included missing floor tiles at the entry to Hall A; loose and peeling baseboards; chipped paint and exposed drywall in several rooms; exposed metal screws; and multiple resident room doors with scratched, missing paint and chipped wood. In Hall B, rooms had chipped drywall, exposed black, white, and green electrical cable wires running from wall vents to the ceiling, and a wall-mount heating/cooling unit with its cover off and lying on the ground outside, covered with leaves and debris. Electrical cords approximately six feet long were hanging from outlets onto walking pathways in Halls B and D. Additional deficiencies included large exposed drywall patches, multiple drywall holes and scratches, crumbling and discolored drywall around heating/cooling units, missing wood framing, and exposed drywall without baseboards in the main dining room. The men’s and women’s visitor bathrooms were posted as out of order over two consecutive survey days, and the AIT acknowledged that the building needed many repairs and that the visitor bathrooms were not operational.
Penalty
Resources
Below are regulatory guidelines relevant to this citation:
Trusted data from CMS and state health departments
Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release July 29, 2026) and official state health department websites — never guesswork.
In your survey window? See what surveyors are citing.
The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.