F0880 F880: Provide and implement an infection prevention and control program.
D

Infection Control Failures During Foley Catheter and Trach Care

Crisp Regional Nsg & Rehab CtrCordele, Georgia Survey Completed on 03-26-2026

Summary

The facility failed to ensure adherence to infection control practices during Foley catheter care for a resident with severely impaired cognition and an indwelling urinary catheter. The resident’s EMR showed no diagnosis for Foley catheter indication, the MDS identified an external catheter, and the care plan contained no Foley catheter care plan. Physician’s orders also did not include an indication for the Foley catheter. During observation, a CNA cleaned the Foley catheter tubing by repeatedly wiping up and down the tubing with the same wipe without folding or disposing of it, then used another wipe to clean around the scrotum and used the same wipe again on the Foley catheter tubing. The CNA later confirmed this was how the care was performed. The facility also failed to maintain standard infection control practices during tracheostomy care for a resident with acute and chronic respiratory failure with hypoxia, cardiac arrest, tracheostomy, and ventilator dependence. The resident’s MDS showed the resident was rarely or never understood and received tracheostomy care and invasive mechanical ventilation. During trach care, the RT removed the dressing from the trach site and placed it on the bare bedside table beside an opened sterile trach set, changed gloves without sanitizing hands, removed the inner cannula and placed it on the bare bedside table, and left the room wearing gown and gloves to retrieve wipes from a cart in the hallway before returning to the room in the same gown and gloves. The RT then used the same gloves used during trach care to press the bed controls and reprogram the ventilator. The report also documented hand hygiene failures by nursing staff. An LPN cleaned a blood pressure cuff, removed gloves, donned a new pair of gloves without sanitizing hands, and then cleaned a blood sugar machine before removing the second pair of gloves and going to the medication cart. Interviews with the RT, RN, UM, infection preventionist, and DON confirmed expectations that hand hygiene should occur before glove use, after glove removal, and between glove changes, and that soiled items should not be placed next to sterile or clean fields.

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0880 citations
Failure to Use EBP, Perform Hand Hygiene, and Maintain Sanitary Laundry Practices
E
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

A resident with an indwelling Foley catheter had EBP identified in the care plan, but staff did not consistently wear gowns during close contact care, including vital signs, medication administration, hygiene-related contact, and topical treatment. In addition, a TMA administered medications to three residents without sanitizing hands between residents or before handling medications, despite policy and DON expectations requiring hand hygiene. Laundry practices were also inconsistent with sanitary handling, as staff sorted soiled laundry without gowns and gloves being available in the room and reported using only gloves for most dirty laundry tasks.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Infection Control Lapses During Insulin Administration
D
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

An LVN failed to follow hand hygiene and insulin pen preparation practices during a medication pass for a resident with diabetes. After washing his hands, he turned off the faucet with his bare hand, then administered insulin without cleaning the insulin pen’s rubber seal with alcohol first. The DON stated both actions were a break in infection control, and the facility policy required proper hand hygiene and noted that gloves do not replace hand hygiene.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Perform Hand Hygiene During Wound Care
D
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

Failure to perform hand hygiene during wound care was identified for a resident with a stage 4 coccyx pressure ulcer, diabetes, CAD, and HTN. An RN and the ADON provided perineal and wound care, but the RN repeatedly changed gloves without sanitizing hands and did not sanitize hands or change gloves before removing soiled packing and applying new wound packing and a dressing. The DON stated staff were expected to sanitize hands every time gloves were removed, and facility policy required hand hygiene after glove removal and before moving from a contaminated body site to a clean body site.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Infection Control Failures During Medication Pass and Respiratory Equipment Storage
D
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

An RN failed to follow hand hygiene and safe medication handling during med pass, including touching dropped tablets and handling meds without gloves or hand hygiene between steps. The facility also failed to store nebulizer mouthpieces and masks in labeled bags when not in use for residents receiving respiratory treatments, including a resident with CHF, CKD, DM2, and anemia. The DON confirmed the expected storage and handling practices were not followed.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Improper Cleaning of Community-Use Glucometer
E
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

An LPN was observed cleaning a community-use glucometer with an alcohol pad instead of the bleach wipe or equivalent required by the facility policy. The LPN stated he always used alcohol pads, while the DNS stated staff were to use bleach wipes. The glucometer was used for CBG checks on several residents with diabetes, and their records did not indicate a BBP.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Use PPE During Wound Care and Replace Oxygen Tubing Timely
E
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

A resident with MRSA and an abdominal wound was observed during wound care with contracted wound care staff entering without proper PPE, touching room items, and performing wound care without consistent hand hygiene or glove changes while moving from dirty to clean tasks; the same staff then went to another resident’s room without gowns despite EBP signage. The facility also failed to timely replace another resident’s oxygen tubing for CPAP/oxygen use, and the tubing had no label showing when it was last changed.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Citation search

Search every citation & Plan of Correction

Go to search
Citation watch

Track new serious citations across Georgia

Get a heads-up on the newest immediate-jeopardy (J–L) citations in Georgia — where surveyors are focused right now.

Free · about one email a month

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release August 26, 2026) and official state health department websites — never guesswork.

In your survey window? See what surveyors are citing.

The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.

Get the Survey-Prep Report
An unhandled error has occurred. Reload 🗙

Connection lost — reconnecting… We couldn't reconnect automatically. Please reload the page to continue.