F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
D

Tube Feeding Water Flush Bags Not Changed per Manufacturer Guidance

Mountain View Conv HospSylmar, California Survey Completed on 03-26-2026

Summary

The facility failed to ensure that enteral feeding residents received appropriate care and services when the water flush bags for two residents with gastrostomy tubes were not changed according to the manufacturer’s recommendations. Resident 119 was admitted with diagnoses including acute respiratory failure with hypoxia, tracheostomy, and gastrostomy, and the record showed tube feeding and free water flush orders. Resident 43 was admitted with diagnoses including acute and chronic respiratory failure with hypoxia, tracheostomy, and gastrostomy, and the record also showed tube feeding and free water flush orders. Both residents were receiving continuous tube feeding through GTs and had care plans directing staff to administer the ordered tube feeding and free water flushes. During observation of both residents in their rooms, the water flush bags were noted to have a date and time indicating they had been hung on the same prior date and time. In interviews, LVN 3 stated the date and time on the tube feeding and water flush bags reflected when the bags were hung, and that the facility’s process was to change the water flush bag when the feeding bag finished. LVN 3 also stated she was not aware that the water flush could not be used for more than 24 hours. During interview and record review, the SAC reviewed the physician orders and the manufacturer’s guideline for the water flush bag. The SAC stated the facility did not follow the manufacturer’s recommendation that the feeding set not be used for more than 24 hours. The facility policy referenced hang times and administration set changes, and the manufacturer’s guideline stated that due to the risk of bacterial contamination and overall system accuracy, feeding sets should not be used for greater than 24 hours.

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0693 citations
Incomplete Enteral Feeding Order for Resident with G-Tube
D
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

A resident with a g-tube, dysphagia, and malnutrition had an enteral feeding order that omitted the formula strength and the administration method. The chart showed the resident was receiving Isosource 1.5 cal bolus feedings, but the active order only stated enteral feed via g-tube. The MDS Coordinator, LVN, and DON all acknowledged the order was incomplete, and the facility policy required enteral nutrition orders to include the product and administration method.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Verify GT Placement Before Medication Administration
D
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

A resident with a GT, GERD, interstitial pulmonary disease, and dementia was observed receiving medications via the GT without the nurse confirming tube placement. The LVN stated she did not check GRV before administering the medications, and the RN and DON stated GT placement and residuals should be checked prior to medication administration, although the facility policy did not include GRV checking.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Inadequate G-tube care and enteral feeding documentation
E
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

Inadequate G-tube care and enteral feeding documentation. A resident with CVA-related hemiplegia and dysphagia had orders for NPO status, continuous Jevity 1.5 via G-tube, water flushes, residual checks every shift, and oral care, but the record lacked an order for tube placement verification or shift site care. MAR/TAR review showed no consistent documentation of G-tube site care or residual checks, water flushes were not always documented as ordered, and feeding amounts were recorded in two places with inconsistent entries; nursing notes were also not present for every shift.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Delayed G-tube Feeding Administration
D
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

A resident with a g-tube, severe cognitive impairment, and dependence on staff for all nutrition and hydration did not receive continuous tube feeding at the ordered start time. The feeding pump was observed off while the resident was away from his room and remained off after he returned from the Day Center; an LVN later connected the feeding after changing the g-tube dressing. Staff stated the resident often returned after the ordered start time and was therefore not hooked up as ordered.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Resident with G-tube was fed while lying flat
D
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

A resident with a G-tube was observed lying supine and below 30 degrees while enteral feeding was running. A CNA said the resident was lower than she should have been during the feeding and that the tube feeding should be turned off when repositioning is needed. An LVN later confirmed the resident should not be lying flat during feeding, paused the tube feeding, and said the resident needed assistance to be safely elevated; the DON stated the head should be elevated above 30 to 45 degrees and never flat during feeding.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Verify G-Tube Placement Before Medications and Water Administration
D
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

Failure to Verify G-Tube Placement Before Medications and Water Administration: An LPN administered crushed meds and water through a resident’s PEG tube without routinely checking tube placement first. The resident had dysphagia, cognitive impairment, and received most calories and fluids via the feeding tube. The RN and DON also indicated uncertainty about whether placement checks were still required, and no provider order exempting the resident from placement verification was found, despite the facility policy requiring placement checks before tube feedings and meds.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Citation search

Search every citation & Plan of Correction

Go to search
Citation watch

Track new serious citations across California

Get a heads-up on the newest immediate-jeopardy (J–L) citations in California — where surveyors are focused right now.

Free · about one email a month

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release August 26, 2026) and official state health department websites — never guesswork.

In your survey window? See what surveyors are citing.

The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.

Get the Survey-Prep Report
An unhandled error has occurred. Reload 🗙

Connection lost — reconnecting… We couldn't reconnect automatically. Please reload the page to continue.