Failure to Maintain Nursing Staff Competency, CPR Certification, and Appropriate Emergency Response
Summary
The facility failed to ensure nursing staff demonstrated and maintained competency to safely provide care and services in accordance with professional standards. Review of CNA personnel files showed that 16 of 34 CNAs did not have current CPR certification, despite the facility’s CNA job description requiring CPR training after employment and maintenance of CPR certification. The Director of Staff Development (DSD) stated the facility did not require CNAs to maintain current CPR certification, acknowledged CNAs were hired with valid CPR that was allowed to expire, and confirmed there were no mock code drills documented in staff files. The DON stated she did not know if CNAs were required to be CPR certified but agreed they should be, and stated that the risk of CNAs not being CPR certified could lead to residents’ death. Record review further showed that CNA competency evaluations were not completed annually. CNA files indicated the last competency skills evaluations were done in 2024, and the DSD confirmed she had not completed annual competency evaluations since then, stating that annual skills competency was the method to determine if a CNA was competent to work. The DON stated the DSD was responsible for yearly CNA competency evaluations and that without these evaluations, CNAs might perform patient care not according to facility policies and procedures. For licensed nurses, review of Licensed Nurse Skill Evaluations revealed incomplete documentation for one RN and four LVNs, with missing evaluator initials, employee initials, and dates. The DON confirmed that these evaluations must be fully completed with initials and dates to be valid and stated she was not aware they were incomplete. Additional review of a Licensed Nurse Skill Evaluation for one RN showed that this RN was evaluated for IV therapy by an LVN, even though the DON stated LVNs were not allowed to work with IVs because it was outside their scope of practice. The DON reported she had an LVN assist her with yearly Licensed Nurse Skill Evaluations because she needed help, despite her job description stating she was responsible for ensuring all nursing personnel received annual competency training. In a separate resident emergency event, an RN and an LVN did not follow facility policy and expected emergency procedures. The RN, after being notified by an LVN that a resident had low oxygen saturation, did not assess the resident, did not obtain full vital signs, left the bedside to call 911, did not return to the resident’s room, and did not document vital signs or assessments before or after oxygen administration. The LVN reported the resident “did not look good,” obtained an oxygen saturation of 89%, left the resident alone twice (including to get the crash cart) instead of using the provided walkie talkie to call for help, administered oxygen at 2 L/min without increasing it, did not recall rechecking oxygen saturation, did not check blood pressure because she was busy, and did not document vital signs or assessments before or after oxygen therapy. The DON stated that during an emergency the RN’s role was to assess the resident and delegate tasks, that vital signs must be taken to determine stability, that residents should not be left alone because CPR might be needed, and that staff were expected to use walkie talkies in emergencies. Facility policies on CPR and oxygen administration required staff to be trained in CPR/BLS, participate in mock codes, assess residents before and during oxygen therapy, obtain and document vital signs and lung sounds, and document all assessment data and oxygen therapy details.
Penalty
Resources
Below are regulatory guidelines relevant to this citation:
Trusted data from CMS and state health departments
Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release August 26, 2026) and official state health department websites — never guesswork.
In your survey window? See what surveyors are citing.
The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.