F0880 F880: Provide and implement an infection prevention and control program.
E

Inadequate Hand Hygiene and Aseptic Technique During Wound and Catheter Care

Ashley Rehabilitation And Health Care CenterRogers, Arkansas Survey Completed on 04-28-2026

Summary

The deficiency involves the facility’s failure to provide wound care in a manner that prevented infection for two residents receiving wound treatments. For the first resident, who had cellulitis, type 2 diabetes mellitus, protein-calorie malnutrition, venous insufficiency of both lower extremities, chronic venous hypertension with inflammation, candidiasis of the skin and nails, and a stage 2 pressure ulcer to the sacrum, the Treatment Nurse (TN), who was also the Infection Preventionist (IP), did not consistently perform hand hygiene or maintain a clean field. During wound care, the TN handled personal items such as keys, a cell phone, and the computer, then accessed wound care supplies from the treatment cart without performing hand hygiene afterward. The TN touched gauze pads with ungloved hands, sprayed them with wound cleanser, and later used those same gauze pads to cleanse the resident’s wound. The TN also set up supplies on a bathroom counter using a non‑impervious paper towel as a barrier, contrary to facility policy requiring an impervious barrier, and did not date or initial the new dressing. For the second resident, who had diagnoses including congestive heart failure, protein-calorie malnutrition, hypertension, GERD, neuromuscular bladder dysfunction, a stage 3 pressure ulcer of the right hip, urethrocutaneous fistula, UTI, and an indwelling catheter, the TN again failed to follow infection prevention practices during wound care. The TN unlocked the treatment cart with keys from her pocket, returned the keys to her pocket, and touched the computer before retrieving wound care supplies, then proceeded without performing hand hygiene until later in the process. She prepared gauze pads in cups with wound cleanser while gloved, then removed her gloves and continued the setup. In the resident’s room, she cleaned only half of the bedside table with a wet, soapy paper towel and dried it with another towel, then placed a non‑impervious paper towel as a barrier for wound supplies, while the other half of the table remained cluttered with personal items including a basin with cups and straws hanging over the wound supplies. During the wound care for the second resident, the TN washed her hands in the bathroom for approximately six seconds before donning gloves. She removed the old dressing from the right hip pressure ulcer, changed gloves, and then used gauze from one cup to clean the hip pressure ulcer. Without performing hand hygiene or changing gloves between dirty and clean tasks, she then used gauze from a second cup to clean the resident’s suprapubic catheter site, which she stated had drainage and had been cauterized the previous week. After removing her gloves, she did not perform hand hygiene before placing a split drain gauze around the suprapubic catheter and applying calcium alginate and a bordered foam dressing to the right hip wound. The TN later acknowledged that she did not wash her hands when going from dirty to clean tasks, that she should have changed gloves before moving to the secondary dressing, and that she had not received wound care training from the facility despite functioning as the wound care nurse and IP. Facility policies required clean technique, prevention of supply and surface contamination, use of an impervious barrier, handwashing after removing dirty gloves and before donning clean gloves, and labeling new dressings with initials, date, and time, as well as adherence to handwashing guidelines consistent with CDC recommendations for at least 15 seconds of rubbing. Interviews with the TN, Nurse Practitioner (NP), and Director of Nursing (DON) further clarified the expectations and deviations from practice. The TN stated she believed she performed hand hygiene when entering rooms and after touching anything dirty, but acknowledged she did not wash her hands between dirty and clean tasks and recognized that setting up wound supplies next to personal items would be an infection control issue. The NP stated that the suprapubic catheter and pressure ulcer should be cleaned one at a time and not treated simultaneously, and that she would not want wound contaminants introduced to the suprapubic catheter. The DON reported that the TN had been performing wound care since around November, had no wound care certification, and had received no specific wound care training from the facility, although the DON believed the TN had prior wound care experience elsewhere. The DON stated that staff should clean hands and change gloves when going from dirty to clean tasks, that separate areas such as a suprapubic catheter and a pressure ulcer should not be treated at the same time due to infection concerns, that dressings should be dated as a standard practice, that bedside tables should be clean, uncluttered, and disinfected rather than just washed with soap and water, and that a brief six‑second handwash was not appropriate.

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0880 citations
Failure to Use EBP, Perform Hand Hygiene, and Maintain Sanitary Laundry Practices
E
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

A resident with an indwelling Foley catheter had EBP identified in the care plan, but staff did not consistently wear gowns during close contact care, including vital signs, medication administration, hygiene-related contact, and topical treatment. In addition, a TMA administered medications to three residents without sanitizing hands between residents or before handling medications, despite policy and DON expectations requiring hand hygiene. Laundry practices were also inconsistent with sanitary handling, as staff sorted soiled laundry without gowns and gloves being available in the room and reported using only gloves for most dirty laundry tasks.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Infection Control Lapses During Insulin Administration
D
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

An LVN failed to follow hand hygiene and insulin pen preparation practices during a medication pass for a resident with diabetes. After washing his hands, he turned off the faucet with his bare hand, then administered insulin without cleaning the insulin pen’s rubber seal with alcohol first. The DON stated both actions were a break in infection control, and the facility policy required proper hand hygiene and noted that gloves do not replace hand hygiene.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Perform Hand Hygiene During Wound Care
D
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

Failure to perform hand hygiene during wound care was identified for a resident with a stage 4 coccyx pressure ulcer, diabetes, CAD, and HTN. An RN and the ADON provided perineal and wound care, but the RN repeatedly changed gloves without sanitizing hands and did not sanitize hands or change gloves before removing soiled packing and applying new wound packing and a dressing. The DON stated staff were expected to sanitize hands every time gloves were removed, and facility policy required hand hygiene after glove removal and before moving from a contaminated body site to a clean body site.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Infection Control Failures During Medication Pass and Respiratory Equipment Storage
D
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

An RN failed to follow hand hygiene and safe medication handling during med pass, including touching dropped tablets and handling meds without gloves or hand hygiene between steps. The facility also failed to store nebulizer mouthpieces and masks in labeled bags when not in use for residents receiving respiratory treatments, including a resident with CHF, CKD, DM2, and anemia. The DON confirmed the expected storage and handling practices were not followed.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Improper Cleaning of Community-Use Glucometer
E
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

An LPN was observed cleaning a community-use glucometer with an alcohol pad instead of the bleach wipe or equivalent required by the facility policy. The LPN stated he always used alcohol pads, while the DNS stated staff were to use bleach wipes. The glucometer was used for CBG checks on several residents with diabetes, and their records did not indicate a BBP.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Use PPE During Wound Care and Replace Oxygen Tubing Timely
E
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

A resident with MRSA and an abdominal wound was observed during wound care with contracted wound care staff entering without proper PPE, touching room items, and performing wound care without consistent hand hygiene or glove changes while moving from dirty to clean tasks; the same staff then went to another resident’s room without gowns despite EBP signage. The facility also failed to timely replace another resident’s oxygen tubing for CPAP/oxygen use, and the tubing had no label showing when it was last changed.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Citation search

Search every citation & Plan of Correction

Go to search
Citation watch

Track new serious citations across Arkansas

Get a heads-up on the newest immediate-jeopardy (J–L) citations in Arkansas — where surveyors are focused right now.

Free · about one email a month

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release August 26, 2026) and official state health department websites — never guesswork.

In your survey window? See what surveyors are citing.

The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.

Get the Survey-Prep Report
An unhandled error has occurred. Reload 🗙