Improper Mechanical Lift Use and Inadequate Sling Selection for Dependent Transfers
Penalty
Summary
The deficiency involves the facility’s failure to ensure safe use of total body mechanical lifts and appropriate slings for residents requiring two-person assistance for transfers. Contracted travel CNAs and facility CNAs used incompatible or improperly sized and positioned slings, and staff lacked clear, accessible information on which sling size and type to use for specific residents. Surveyors identified that staff often selected sling sizes based on visual estimation of body size or by using whatever sling was present in the room, rather than following resident-specific guidance. Care plans and Kardexes for multiple residents who required mechanical lifts did not specify the type of lift (full body or sit-to-stand) or the correct sling size, leaving staff without written direction. One incident involved a resident who had been admitted earlier that day with a full body lift sling brought from the hospital. During a transfer from wheelchair to bed using a full body lift, two CNAs attached the sling provided by the family and began the transfer. As one CNA attached the lower body sling straps to the lift hooks, the resident moved and slid forward in the sling. The CNAs readjusted the resident and completed attaching the sling, but the resident continued to move and slid toward the edge of the wheelchair seat, causing the sling to tilt downward. Unable to safely complete the transfer, the CNAs lowered the resident to the floor using the upper portion of the sling while the lower portion remained attached to the lift. The resident’s buttocks contacted the floor first, she was then assisted to a lying position, and she reported rib pain; a subsequent chest X-ray showed no breaks or fractures. This event was identified as the start of Immediate Jeopardy at F689. Another observed incident involved a different resident being transferred from a wheelchair to a bed using a full body lift and a burgundy (large) sling. Two contracted travel CNAs placed the sling behind the resident, pulled the lower straps under her thighs, and interlaced the straps. As they began lifting, the resident’s wheelchair pad and the left handle of the wheelchair became caught in the sling, causing the wheelchair to lift off the floor with the resident still seated. While the resident and wheelchair were suspended, one CNA pulled on the wheelchair pad to free it, and the CNAs switched tasks while the resident remained in the air. After lowering the resident and wheelchair back to the floor and freeing the wheelchair handle, they did not reposition the sling, which was noted to be placed too high, with the bottom of the sling at the resident’s mid-back instead of under her buttocks. They then lifted the resident again and transferred her to the bed, with one CNA stating during the lift that the setup was “all wrong.” Interviews with multiple CNAs and nursing staff revealed that many had not received recent or any facility-specific training or competencies on safe use of mechanical lifts and sit-to-stand lifts. Several CNAs reported choosing sling sizes based on the resident’s body type or guessing, and one CNA stated she relied on training from previous employers. Staff were generally unaware of which sling to use for specific residents and could not readily locate up-to-date written resources; binders that were supposed to contain lift and sling information were missing or outdated. A paper list of sling sizes found in a communication binder was acknowledged by an RN as not updated. Another RN stated she did not know residents’ sling sizes and would ask a CNA for guidance. Record review confirmed that not all direct care staff, including CNAs involved in the incidents, had completed required competencies on total body lifts or sit-to-stand lifts after the reported incident, despite having worked shifts since that time. Further review of resident records showed that for several residents who used mechanical lifts, care plans and Kardexes lacked documentation of sling size and, in some cases, did not even specify the type of lift to be used. For example, one resident’s care plan and Kardex indicated a need for two-person assistance with transfers but did not identify any transfer equipment. Surveyors also compared an updated list of transfer equipment to slings stored in residents’ rooms and found discrepancies between listed sling sizes and those actually present or documented in the Kardex for certain residents. The facility’s own sling sizing chart and manufacturer’s instructions for the EZ Way Smart Lift outlined proper sling positioning and sizing parameters, including that the base of the sling should be positioned two inches below the tailbone and the top parallel with the shoulder line, but observed practice and staff statements demonstrated that these guidelines were not consistently followed.