F0641 F641: Ensure each resident receives an accurate assessment.
D

MDS Incorrectly Coded Anticoagulant Use

York General HearthstoneYork, Nebraska Survey Completed on 03-09-2026

Summary

The facility failed to accurately code Resident 2’s admission MDS to reflect that an anticoagulant was being given. Record review showed the resident was admitted with a BIMS score of 14, indicating cognitive intactness, and the MDS documented use of an oral antibiotic and an anticoagulant. However, the facility initiated care plan dated 12/30/2025 stated the resident was at risk for abnormal bleeding or hemorrhage because of anticoagulant use and directed staff to administer anticoagulants as prescribed by the physician. During interviews, RN-B confirmed that Resident 2 had not taken an anticoagulant since admission and stated the resident was admitted on Plavix. RN-A also confirmed that the MDS was marked incorrectly and that the resident had not taken an anticoagulant since admission to the facility. Review of the CMS RAI Manual N0415 showed that antiplatelet medications such as clopidogrel are not to be coded as an anticoagulant.

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0641 citations
Inaccurate MDS Assessments for Medication Use and Diagnoses
E
F0641 F641: Ensure each resident receives an accurate assessment.
Short Summary

A facility failed to ensure MDS assessments accurately reflected resident status for several residents. One resident’s admission MDS listed insulin injections even though she received liraglutide, while two other residents’ MDSs omitted antidepressant, opioid, and scheduled pain medication use despite active orders and MAR documentation. Another resident’s quarterly MDS failed to include respiratory failure as an active dx even though the record, orders, and resident interview confirmed the condition and oxygen use.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Inaccurate Resident Assessments
D
F0641 F641: Ensure each resident receives an accurate assessment.
Short Summary

Inaccurate resident assessments were identified for multiple residents when MDS coding did not match the clinical record, observations, or staff statements. One resident was coded as having a restraint-related chair device despite no restraints being observed or ordered, another was coded as not receiving antibiotics despite MAR documentation of mupirocin use, and two other residents had missing or incorrect MDS entries for diagnoses, ROM status, and skin/wound conditions based on admission records, physician notes, wound care documentation, and staff interviews.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Inaccurate MDS Coding for Weight Loss and Active Diagnoses
D
F0641 F641: Ensure each resident receives an accurate assessment.
Short Summary

Inaccurate MDS coding affected two residents. One resident had significant weight loss documented in the EHR, but the quarterly MDS did not reflect the loss as required. Another resident with lung cancer and metastatic disease had an admission MDS that omitted active cancer diagnoses from section I. The MDS/LPN acknowledged the missing diagnosis, and the DON stated MDS assessments were expected to be coded accurately.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Inaccurate MDS Assessments for Oxygen Use, Depression, and Range of Motion
D
F0641 F641: Ensure each resident receives an accurate assessment.
Short Summary

A facility failed to ensure MDS assessments accurately reflected resident status for multiple residents. One resident’s oxygen use was not captured in Section O despite PRN O2 orders and repeated oxygen saturation documentation, another resident’s MDS omitted oxygen use despite progress notes and an O2 order, a third resident’s MDS omitted depression despite a citalopram order, and a fourth resident’s MDS coded no ROM impairment even though PT identified quadriplegia with limitations in all extremities.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Inaccurate MDS Weight Loss Coding
D
F0641 F641: Ensure each resident receives an accurate assessment.
Short Summary

A resident’s quarterly MDS incorrectly coded significant weight loss even though his documented weights did not show 5% loss in 1 month or 10% loss in 6 months. The MDS RN said she based the coding on weight fluctuations and medication changes rather than actual loss during the look-back period, and the resident’s care plan continued to reflect significant unplanned weight loss, poor intake, and anxiety.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Inaccurate MDS Coding for Diabetes Medications
D
F0641 F641: Ensure each resident receives an accurate assessment.
Short Summary

Inaccurate MDS coding was found for two residents whose diabetes meds were non-insulin injectables. One resident with ESRD and diabetes had Ozempic ordered, and another resident with CKD and diabetes had Mounjaro ordered, but both MDS assessments incorrectly coded insulin use and hypoglycemic drug class use. The MDS coordinator acknowledged the coding error but did not update the assessments after learning of the inaccuracy.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Citation search

Search every citation & Plan of Correction

Go to search
Citation watch

Track new serious citations across Nebraska

Get a heads-up on the newest immediate-jeopardy (J–L) citations in Nebraska — where surveyors are focused right now.

Free · about one email a month

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release July 29, 2026) and official state health department websites — never guesswork.

In your survey window? See what surveyors are citing.

The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.

Get the Survey-Prep Report
An unhandled error has occurred. Reload 🗙