F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
D

Feeding Tube Orders and Documentation Not Followed

Bernard Care CenterSaint Louis, Missouri Survey Completed on 12-19-2025

Summary

The facility failed to ensure physician orders were obtained for feeding tube water flushes and failed to ensure staff documented the date and time the tube feeding formula was hung for one of two residents sampled with feeding tubes, Resident #120. The resident’s quarterly MDS dated 9/22/25 showed mild cognitive impairment and diagnoses including anemia, heart failure, hypertension, peripheral vascular disease, kidney failure, diabetes, hyperkalemia, hyperlipidemia, aphasia, CVA, hemiplegia, seizure disorder, malnutrition, and depression. The resident weighed 103 pounds and had a feeding tube. The resident’s care plan identified aspiration risk and dehydration or potential fluid deficit related to an NPO diet, with interventions including continuous tube feeding and water flushes per orders. The hospital record showed the resident was hospitalized from 11/19/25 to 12/2/25 for HHS/DKA, septic shock, respiratory failure due to RUL pneumonia, and severe hypernatremia, and underwent g-tube replacement on 12/1/25 after the tube was dislodged. The discharge record indicated continuous tube feed at 55 ml/hr of Glucerna 1.5 cal, but no documentation of water flushes, rate, or frequency. The physician orders for December 2025 included NPO status, Glucerna 1.5 at 55 ml per hour, a prior order for 150 cc water flush via g-tube every four hours, discontinuation of that flush order, and a later order for 150 cc free water every four hours via pump related to hyperkalemia. During observations from 12/15/25 through 12/19/25, the resident was seen with tube feeding infusing at 55 ml/hr, but the formula bottle had no documentation of the time it was hung and started infusing on multiple occasions. The g-tube pump also showed varying water flush settings, including 100 cc every hour and 150 cc every four hours. The DON stated she expected staff to ensure the resident had physician orders for water flushes, to follow physician orders, and to document the date, time, infuse rate, and formula type on the bottle; she also stated that when the resident returned from the hospital, he/she was on 100 ml water flush.

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0693 citations
Incorrect Enteral Feeding Rate
D
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

A resident with a feeding tube, severe cognitive impairment, quadriplegia, and persistent vegetative state was observed receiving g-tube feeding at 55 mL/hr even though the physician order specified Isosource 1.5 at 85 mL/hr for 22 hours. An LVN confirmed the incorrect pump rate and stated he was unsure why it was set that way, while the DON and ADM stated staff were expected to verify orders and pump settings and that nursing was responsible for tube feeding administration.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Feeding Tube Left Infusing While Resident Was Flat During Care
D
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

A resident with a G-tube, CVA, dysphagia, and severe cognitive impairment was observed receiving incontinent care with the HOB flattened while tube feeding continued to infuse. Two CNAs did not call the nurse to stop the pump before care, and the resident remained flat for 36 minutes while appearing uncomfortable. Interviews confirmed staff knew the pump should be stopped and that only nurses handle the tube and pump.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Tube Feeding Administration and Documentation Deficiencies
D
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

Two residents with feeding tubes had enteral nutrition documented inconsistently with provider orders. For one resident, staff recorded pump on/off times but not the total amount infused; for another resident, nurses only initialed shifts without documenting actual start/stop times or fluid amounts. An LPN, resident care manager, and DON acknowledged the documentation did not meet expectations.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Tube Feeding Formula and Flush Bag Not Dated or Labeled
D
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

A resident with severe cognitive impairment and tube feeding orders had formula and a water flush bag that were not dated or labeled. The care plan addressed tube feeding, aspiration monitoring, and keeping the HOB elevated, and an RN stated she checks placement, primes the pump, and verifies the formula is not expired, labeled, and dated. Facility policy required checking the enteral nutrition label against the order, including the resident name, formula type, preparation date and time, and rate of administration.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Verify GT Placement and Residual Before Medication Administration
D
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

An LVN failed to verify GT placement and check GRV before administering medications to a resident with dysphagia, a GT, and severely impaired cognitive skills. The resident’s orders required GT placement/patency checks and residual checks every shift, and the facility policy required tube placement verification and residual checks before medication administration.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Improper Head-of-Bed Positioning During GT Feeding
D
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

Improper Head-of-Bed Positioning During GT Feeding: A resident receiving GT feeding was observed lying in bed with the HOB at 20 degrees while the feeding was actively infusing, despite the care plan and facility P&P directing HOB elevation to 30 to 45 degrees or upright positioning during and after tube feeding. An LVN confirmed the resident should have been at 45 degrees and verified the lower HOB setting during the feeding; the Administrator and DON acknowledged the findings.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Citation search

Search every citation & Plan of Correction

Go to search
Citation watch

Track new serious citations across Missouri

Get a heads-up on the newest immediate-jeopardy (J–L) citations in Missouri — where surveyors are focused right now.

Free · about one email a month

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release July 29, 2026) and official state health department websites — never guesswork.

In your survey window? See what surveyors are citing.

The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.

Get the Survey-Prep Report
An unhandled error has occurred. Reload 🗙