Improper Securing of Suprapubic Catheter Tubing
Penalty
Summary
The deficiency involves the facility’s failure to provide appropriate care and treatment for a resident with a suprapubic catheter by not securing the catheter tubing according to current standards of practice and the facility’s own competency checklist. The resident had multiple urologic and cognitive conditions, including Alzheimer’s disease with severely impaired cognition (BIMS score of four), chronic kidney disease stage three, benign prostatic hyperplasia, obstructive uropathy, and urinary retention, and was documented as having an indwelling catheter. The care plan included an order from the resident’s urologist directing staff not to remove the catheter and directed staff to apply Skin-prep prior to attaching a Stat-lock for the suprapubic catheter. On two separate observations, licensed nurses assessed and cleaned the suprapubic catheter site on the resident’s abdomen but attached the Stat-lock to the resident’s left upper thigh, securing the tubing from the abdomen to the leg. One nurse confirmed the Stat-lock was attached to the thigh and stated they were unaware that a Stat-lock could be adhered to the abdomen. The administrative nurse stated she expected the Stat-lock to be anchored to the leg and acknowledged that the facility catheter policy did not specify Stat-lock placement for a suprapubic catheter. However, she also stated that the facility’s suprapubic catheter replacement competency checklist, which she had previously reviewed, directed that the catheter tubing should be anchored to the abdomen. The competency checklist documented that the catheter tubing should be secured to the abdomen, but this was not followed in practice.