F0689 F689: Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
E

Unsafe Hot Water Temperatures Not Monitored in Resident Areas

Mozaic Senior LifeBridgeport, Connecticut Survey Completed on 09-29-2025

Summary

The facility failed to maintain safe water temperatures and failed to monitor water temperatures in resident rooms and bathrooms to ensure residents were free from potential burns. On 9/22/2025, survey observations found hot water temperatures above 120 degrees Fahrenheit in 25 of 46 rooms observed, ranging from 120.2 degrees Fahrenheit to 148.5 degrees Fahrenheit. In one resident bathroom, the faucet water temperature measured 121.6 degrees Fahrenheit. The resident, who had diagnoses including paroxysmal atrial fibrillation, chronic systolic congestive heart failure, and cardiomyopathy, had a BIMS score of 15 and required partial/moderate assistance for personal hygiene while being independent with oral hygiene, transfers, and walking 150 feet. The resident stated the bathroom water was "hot as anything," had been hot since admission in February 2024, and was especially difficult to regulate in the shower because it was so hot it took a while. Review of the facility's monthly domestic hot water temperature log from 8/1/2025 through 9/21/2025 showed water temperatures recorded high on 23 of 52 days, above 120 degrees Fahrenheit, with no documented plan of correction or measures to protect residents. Interviews with maintenance and physical plant staff showed temperatures were checked daily only at mixing valves in the boiler room, not in resident rooms or care areas, and staff were unaware they should check resident areas after elevated readings. Staff stated they generally adjusted the mixing valves when readings were high, but resident room temperatures were not checked unless there was a complaint. The facility's operations and maintenance manual stated mixing valves and/or anti-scald valves are necessary to reduce final water temperature to no more than 120 degrees Fahrenheit in patient/resident areas to prevent scalding.

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0689 citations
Failure to Ensure Effective Fall Alarms and Supervision
E
F0689 F689: Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
Short Summary

Failure to ensure effective fall alarms and supervision: two residents had Smart Caregiver monitoring devices set to LOW volume, and one resident's bed alarm did not alert staff before the resident was found on the floor after an unwitnessed fall. One resident had dementia, osteoporosis, prior TIA, and cognitive impairment and was fully dependent on staff, while staff also found that a second resident's bed and recliner alarms did not activate properly during testing.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Assess Safety of Perimeter Mattresses
D
F0689 F689: Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
Short Summary

Failure to assess the safety of perimeter mattresses for two residents. Both residents had severely impaired cognition and significant mobility limitations, and both care plans included use of a perimeter mattress to define the edges of the bed. However, their Mobility, Physical Device, and Fall Risk assessments lacked documentation of a perimeter/defined edge mattress assessment. Staff interviews showed inconsistent understanding of the required order, IDT review, engineering review, and safety assessment before use.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Improper Mechanical Lift Transfers
D
F0689 F689: Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
Short Summary

Improper Mechanical Lift Transfers: A resident with dementia, spinal cord dysfunction, and dependence for transfers was supposed to be moved with a full-body mechanical lift and two staff members, but a TMA stated she transferred the resident alone. The resident reported that staff sometimes used only one person for lift transfers because of staffing shortages, while other staff and the DON stated this was unsafe and against policy.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Unsafe Wheelchair Fit and Incomplete Post-Fall Monitoring
D
F0689 F689: Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
Short Summary

Two residents were involved in accident-hazard deficiencies. One resident with cancer, PVD, and Alzheimer’s disease was observed in a wheelchair with feet extending past short footrests, with the lower legs resting against the hard footrests despite a care plan entry for padding. Another resident with dementia and a hx of falls had an unwitnessed fall, but ordered orthostatic BP monitoring was not completed accurately and staff reported no post-fall PT referral was received.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to assess electric wheelchair use and update fall interventions
G
F0689 F689: Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
Short Summary

A resident was given a new electric wheelchair without a prior therapy assessment and could not stop the chair, causing it to strike a bed frame and resulting in a leg laceration, tibia/fibula fractures, and a syncopal episode from blood loss. Another resident with cognitive impairment and high fall risk continued to self-transfer and fall, but the care plan was not updated with new fall interventions after repeated incidents.

Inspection fine: $17,665
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Unsafe One-Person Use of Mechanical Lift
E
F0689 F689: Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
Short Summary

A CNA used a Hoyer lift alone to weigh one resident, and another CNA was observed using a Hoyer lift alone to weigh a second resident. One resident’s care plan called for a 2-assist Hoyer lift, and the facility’s lift competency checklist and policy both required two caregivers for mechanical lift use; the DON and Director of Therapy also stated that two staff members are always required.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Citation search

Search every citation & Plan of Correction

Go to search
Citation watch

Track new serious citations across Connecticut

Get a heads-up on the newest immediate-jeopardy (J–L) citations in Connecticut — where surveyors are focused right now.

Free · about one email a month

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release July 29, 2026) and official state health department websites — never guesswork.

In your survey window? See what surveyors are citing.

The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.

Get the Survey-Prep Report
An unhandled error has occurred. Reload 🗙