F0695 F695: Provide safe and appropriate respiratory care for a resident when needed.
D

Respiratory Equipment and Oxygen Tubing Not Managed as Ordered

Civita Care BayviewWaterford, Connecticut Survey Completed on 12-03-2025

Summary

Safe and appropriate respiratory care was not provided for a resident with sleep apnea, heart failure, and anxiety when BiPAP equipment was not ordered in a timely manner. The resident had a physician’s order for BiPAP at bedtime with oxygen at 2 to 3 liters per minute and the care plan identified use of BiPAP with oxygen to maintain an effective breathing pattern during sleep and restful sleep. The resident reported not having a BiPAP mask for about 2 weeks, and staff interviews showed the resident had been without a mask while several nurses were told masks were needed. The unit secretary or DNS usually ordered BiPAP masks, but the DNS stated the DME company was responsible for ordering BiPAP equipment and fit testing. The resident had refused the current mask because it did not fit and leaked, and the masks were not received until after the delay was identified. Safe and appropriate respiratory care was also not provided for another resident when the facility did not follow a physician’s order to change oxygen tubing weekly. The resident had diagnoses including breast cancer, liver disease, and depression, and a medical director note identified a history of sleep apnea. The care plan identified altered respiratory status or difficulty breathing and use of C-PAP and oxygen. A physician’s order directed oxygen tubing to be changed every Sunday on the 11-7 shift, but observation showed the tubing dated 6/22, over 2.5 months old. An LPN on the 11-7 shift stated the tubing was to be changed weekly but was not sure who was responsible for doing it.

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0695 citations
Oxygen equipment not maintained per order
D
F0695 F695: Provide safe and appropriate respiratory care for a resident when needed.
Short Summary

A resident who required oxygen therapy for SOB had an oxygen bubbler that was overdue for replacement, despite a TAR directing weekly changes of oxygen supplies including the bubbler and tubing. Staff confirmed the bubbler should have been changed weekly, and the DON and staff educator stated nurses were expected to follow the provider order as written and that all disposable oxygen pieces were to be changed weekly.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Bi-pap Therapy Not Ordered or Verified at Admission
E
F0695 F695: Provide safe and appropriate respiratory care for a resident when needed.
Short Summary

A resident with COPD, acute respiratory failure with hypercapnia, and oxygen dependence was admitted with prior records showing nightly Bi-pap use and specific settings, but the facility did not have a Bi-pap order or settings in the chart and the baseline care plan did not address oxygen or Bi-pap. The resident reported he went without Bi-pap for three nights because a connector piece was missing, while the hospice RN, admitting LPN, ADON, and DON each stated they were unaware of the machine or did not verify the equipment and orders at admission.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Respiratory Care and Tracheostomy Care Not Provided as Ordered
D
F0695 F695: Provide safe and appropriate respiratory care for a resident when needed.
Short Summary

Respiratory care was not provided as ordered for one resident receiving O2, as the NC tubing was not dated. Tracheostomy care was also not provided as ordered for another resident: heavy thick mucus was visible under the trach, the ATM mask was soiled with mucus, the ATM and nebulizer tubing were not dated or stored in a bag, and the suction catheter tubing end was not stored in a bag. An RN confirmed the findings.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Change Oxygen Equipment per Physician Orders
D
F0695 F695: Provide safe and appropriate respiratory care for a resident when needed.
Short Summary

The facility failed to follow physician orders for oxygen equipment for two residents with COPD-related diagnoses. Observations showed each resident’s O2 tubing and water bottle remained dated and unchanged beyond the ordered weekly schedule, and the DON confirmed the equipment should have been changed per the orders.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Maintain Ordered Continuous Oxygen
D
F0695 F695: Provide safe and appropriate respiratory care for a resident when needed.
Short Summary

Failure to maintain ordered continuous O2: A resident with stroke and COPD was observed without his NC while a CNA waited for a portable O2 unit to be filled. The CNA then applied the NC but did not turn on the liquid portable O2, and later wheeled the resident to the nurse’s station to have the nurse set the unit to the ordered liter flow. The resident’s physician had ordered continuous O2 2L to 4L NC.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Improper Storage of CPAP Mask and Oxygen Tubing
D
F0695 F695: Provide safe and appropriate respiratory care for a resident when needed.
Short Summary

Improper Storage of CPAP Mask and Oxygen Tubing: A resident with COPD, DM, dialysis dependence, and continuous O2 orders had his CPAP/NIV mask observed lying on the bedside table and his O2 tubing wrapped under the concentrator handle instead of being stored in a sanitary container or bag. Staff interviews confirmed the equipment should be stored in a bag when not in use, but it was not being kept that way during observation.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Citation search

Search every citation & Plan of Correction

Go to search
Citation watch

Track new serious citations across Connecticut

Get a heads-up on the newest immediate-jeopardy (J–L) citations in Connecticut — where surveyors are focused right now.

Free · about one email a month

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release October 8, 2026) and official state health department websites — never guesswork.

In your survey window? See what surveyors are citing.

The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.

Get the Survey-Prep Report
An unhandled error has occurred. Reload 🗙

Connection lost — reconnecting… We couldn't reconnect automatically. Please reload the page to continue.