Unsafe and Water-Damaged Resident Areas
Summary
The facility failed to provide a safe, sanitary, functional, and comfortable environment in multiple areas, including a resident shower room, a corridor outside that shower room, a resident room sink faucet, and two resident personal bathrooms. Survey observations found that one shower room had four 12-by-12 inch wall tiles on the lowest part of the shower wall held in place with strips of duct tape, with a visible gap and black substance beneath one tile, bowing when pressure was applied, warping and peeling paint around the wall and door frame, and soft, disintegrated wood at the bottom of the door frame. The same shower room also had a shower head that continuously leaked water down the wall and onto the floor, leaving a visible puddle. Record review and staff interviews showed the maintenance director had been notified of the loose tiles weeks earlier and had been working on the shower room in stages while residents continued to use it. He stated he had no documentation of the repairs and was not aware of the shower head leak at first, later stating he had replaced the shower head but had no documentation of the purchase, installation, or work order. He also acknowledged that the leak and daily use of the shower room could contribute to water damage and that he should have closed the shower room sooner. The nursing home administrator later stated the shower room would be closed until the interior and exterior water damage were addressed. Surveyors also observed water damage in the corridor outside the shower room, where the carpet and baseboard were discolored, soft, and damp. The maintenance director initially said he was not aware of the damage, then later said he had used carpet fans to dry the area and was waiting to finish the shower room repairs before repairing the corridor. In addition, one resident room had a dripping bathroom sink faucet, and two resident personal bathrooms had water-damaged walls and ceilings with peeled, missing, bubbled, and discolored paint. The maintenance director said he had not been aware of the faucet drip or the bathroom wall damage and stated that housekeepers had not reported the issues to him. He also identified the bathroom damage as water damage and linked it to a previously leaking toilet on the second floor.
Penalty
Resources
Below are regulatory guidelines relevant to this citation:
Trusted data from CMS and state health departments
Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release July 29, 2026) and official state health department websites — never guesswork.
In your survey window? See what surveyors are citing.
The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.