Kitchen Staff Competency for Sanitizer Testing
Summary
The facility failed to ensure that one of three sampled kitchen staff members, Dietary Aide 2, was routinely trained and evaluated for competency related to kitchen duties. During an observation in the kitchen, Dietary Aide 2 was sanitizing dishes in a sanitizer solution made with QUAT sanitizer. When asked to check the sanitizer solution concentration, Dietary Aide 2 first attempted to use the dish machine sanitizer test strip, which is for chlorine sanitizer, instead of the correct test strip for the manual dishwashing sanitizer solution. Dietary Aide 2 stated the test strip was not working, identified the normal range as 100 PPM, and said the color change should be blue. The Dishwasher staff then provided the correct test strip, and Dietary Aide 2 immersed it in the sanitizer solution and counted for 20 seconds to read the result. Dietary Aide 2 also stated that dishes must be submerged in the sanitizer solution for five to ten minutes before being removed to air dry. During interview, the Dietary Supervisor stated Dietary Aide 2 was using the wrong test strip to test the sanitizer solution concentration and that kitchen staff needed to know how to check solutions. The Dietary Supervisor stated that if kitchen staff did not check the sanitizer correctly, the dishes could potentially be contaminated and not sanitized. The Dietary Supervisor also stated that in-services had been provided to staff on sanitizer solutions and how to check for concentration, but did not know whether the annual competency review included sanitizer solution testing. Review of the Dietary Aide job description showed general duties and responsibilities to wash and clean utensils as directed, and the facility's annual dietary competency evaluation did not list manual dishwashing or checking sanitizer concentration for review. The manufacturer procedure for manual pot and pan washing stated to submerge items in the sanitizer sink for one minute or as specified by the product label, and the posted manufacturer recommendation for sanitation range testing stated the solution should be tested at room temperature, dipped for 10 seconds, compared immediately to the package scale, and maintained between 150 and 400 PPM.
Penalty
Resources
Below are regulatory guidelines relevant to this citation:
Trusted data from CMS and state health departments
Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release July 29, 2026) and official state health department websites — never guesswork.
In your survey window? See what surveyors are citing.
The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.