Failure to Rotate Subcutaneous Injection Sites
Summary
The facility failed to ensure that subcutaneous insulin was administered with rotation of injection sites for a resident with type 2 diabetes mellitus, end stage renal disease, and encephalopathy. The resident’s orders included insulin lispro before meals and at bedtime with instructions to rotate the site, and the care plan also directed insulin administration as ordered. The location of administration record showed repeated use of the same general areas, including the left upper arm/rear upper arm on multiple occasions and the left arm/forearm on multiple occasions, rather than rotating sites as ordered. During a concurrent interview and record review, the ADON confirmed that there were multiple instances where licensed staff did not rotate the resident’s insulin administration sites as reflected in the record. The ADON stated there was an order to rotate the administration sites and that the staff did not follow the physician’s order, constituting a medication error. The ADON also stated that failure to rotate insulin injection sites can lead to lipodystrophy. The facility’s insulin administration policy stated that injection sites should be rotated to reduce the risk of damaging skin tissue, and the medication errors policy defined significant medication errors as administration not in accordance with the prescriber’s order, manufacturer’s specifications, or accepted professional standards. The facility also failed to rotate subcutaneous enoxaparin administration sites for another resident admitted with a displaced fracture of the right femur and ordered enoxaparin 40 mg subcutaneously daily for post-operative prophylaxis with instructions to rotate sites. The location of administration record showed enoxaparin given on consecutive days at the right arm. During direct observation, an LVN prepared and administered the enoxaparin injection to the resident at the right shoulder, then later checked the electronic record and found the last site had also been the right arm. The LVN stated he should have checked the record for the last administration site before giving the medication and acknowledged that not rotating the site was a medication error. The ADON also stated the injection should have been rotated and that staff should check the history of the last site in the electronic record before administering subcutaneous medications that require rotation.
Penalty
Resources
Below are regulatory guidelines relevant to this citation:
Trusted data from CMS and state health departments
Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release October 8, 2026) and official state health department websites — never guesswork.
In your survey window? See what surveyors are citing.
The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.