F0641 F641: Ensure each resident receives an accurate assessment.
D

Inaccurate MDS Coding for Resident Behaviors and GDR Documentation

Seacrest Rehabilitation And Healthcare CenterLittle Egg Harbor Tw, New Jersey Survey Completed on 12-19-2025

Summary

The facility failed to accurately code the Minimum Data Set (MDS) for Resident #9, who was admitted with diagnoses including depression and schizoaffective disorder. The quarterly MDS dated 9/23/2025 showed a BIMS score of 3 out of 15, indicating severe cognitive impairment, yet it also indicated that the resident exhibited no behaviors during the assessment reference period. During the survey, the resident was observed confused and wandering into other residents’ rooms, and staff were seen redirecting the resident. The interdisciplinary care plan documented behaviors including wandering, refusing medications, and physical behaviors during care. The annual MDS also contained inaccurate coding in Section N regarding gradual dose reduction (GDR) of antipsychotic medication. Progress notes showed that Seroquel was reduced from 25 mg daily to 12.5 mg daily on 6/5/25, and later increased back to 25 mg daily after the psychiatrist documented increased behaviors following the GDR. However, the annual MDS indicated that a GDR had not been attempted, despite documentation confirming that a GDR was attempted on 6/6/25 and later found contraindicated on 6/26/25, which was three days after the assessment reference date. The MDS coordinator stated that assessments are completed using resident interviews, electronic records, and staff communication, and that the DON signs the MDS after completion by the LPN.

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0641 citations
MDS Did Not Reflect Resident’s Dialysis Treatments
D
F0641 F641: Ensure each resident receives an accurate assessment.
Short Summary

A resident with CKD stage 5 and ESRD had an MDS that did not indicate dialysis in Section O, even though the resident had active orders for dialysis, a care plan for dialysis-related needs, and staff confirmed he was receiving dialysis at an outside clinic on a regular schedule. The MDS nurse stated dialysis should have been triggered on the assessment and described the omission as an oversight/data entry error.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Inaccurate MDS Coding for Oxygen Use
D
F0641 F641: Ensure each resident receives an accurate assessment.
Short Summary

A facility failed to accurately code oxygen use in the MDS for 3 residents reviewed for respiratory services. Each resident had physician orders for oxygen and vitals documentation showing oxygen via NC or mask, but the Quarterly MDS assessments did not record oxygen use in Section O. The MDS Coordinator stated the assessments needed to be modified because the charting showed oxygen use, and the DON stated the facility follows the RAI.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
MDS Assessments Incorrectly Coded for Falls and PASRR
E
F0641 F641: Ensure each resident receives an accurate assessment.
Short Summary

MDS assessments were inaccurately coded for falls and PASRR for multiple residents. One resident’s MDS did not fully reflect two documented falls, including one with a major injury, and several residents with documented Level II PASRR determinations were coded as not currently considered by the state PASRR process to have SMI/ID or a related condition. Staff interviews confirmed the chart contained the PASRR information, but the MDS entries did not match the record.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Inaccurate MDS Coding for Bedrail Use
D
F0641 F641: Ensure each resident receives an accurate assessment.
Short Summary

Inaccurate MDS Coding for Bedrail Use. The facility failed to accurately code the MDS for two residents reviewed for bedrail use. Both residents were cognitively intact and had diagnoses including cardiac conditions and high blood pressure, and both MDS assessments stated they did not use bedrails. However, surveyors observed quarter bed rails on both sides of each bed, and the medical records did not indicate bedrail use. The DON stated the MDS must be accurate because it drives the resident plan of care and reimbursement.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
MDS Assessment Did Not Reflect Resident Behaviors
D
F0641 F641: Ensure each resident receives an accurate assessment.
Short Summary

MDS assessment did not accurately capture a resident’s ongoing behaviors during ADL care. The resident had dementia, anxiety, depression, and diabetes with neuropathy, and staff and family described repeated episodes of screaming, cursing, hitting, scratching, resisting care, and attempting to bite during personal care and transfers. CNA notes and the MAR did not clearly document the behaviors, the care plan did not address them, and the MDS nurse said she did not interview nursing staff or review CNA documentation when completing the assessment.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Inaccurate MDS Mobility Assessment
D
F0641 F641: Ensure each resident receives an accurate assessment.
Short Summary

A resident with a hx of cerebral infarction, HTN, and generalized muscle weakness had an inaccurate MDS mobility assessment. The MDS documented use of a walker and wheelchair, while rehab, RNA, IDT notes, and staff interviews showed the resident ambulated with a single point cane and was highly functioning. The DON and ADON stated the MDS was not accurate, and the MDSN confirmed the cane use was not reflected.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Citation search

Search every citation & Plan of Correction

Go to search
Citation watch

Track new serious citations across New Jersey

Get a heads-up on the newest immediate-jeopardy (J–L) citations in New Jersey — where surveyors are focused right now.

Free · about one email a month

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release August 26, 2026) and official state health department websites — never guesswork.

In your survey window? See what surveyors are citing.

The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.

Get the Survey-Prep Report
An unhandled error has occurred. Reload 🗙

Connection lost — reconnecting… We couldn't reconnect automatically. Please reload the page to continue.