Failure to Provide Safe and Appropriate Resident Equipment
Summary
The facility failed to reasonably accommodate the needs and preferences of two residents when durable medical equipment was not provided in a condition that matched their functional care needs. One resident, admitted with a femur fracture, dementia, insomnia, and posterior hip precautions after hip fracture, reported that the toilet safety frame over the toilet was crooked and unsafe. The frame was observed to be worn and rusted at one leg, with one caster about an inch higher than the others so it did not rest on the ground. The commode seat/frame moved back and forth and was wobbly, and the resident stated they felt nervous using the toilet and feared falling. Staff acknowledged the safety concern and removed the frame. The second resident, admitted with a right femur fracture, interstitial lung disease, insomnia, depression, and anxiety, was observed lying in a hospital bed that did not fit their frame. The resident stated they had repeatedly asked for a new bed because the bed was too short for their height and uncomfortable for sleep. When lying on their back, their legs extended off the foot of the bed, and when lying on their left side they were directly on the trochanteric area where a pressure injury was present. The resident also reported pain in the left hip and back, pain on the right hip where a surgical wound was located, and difficulty sleeping because the bed was uncomfortable. Record review showed the resident had a facility-acquired pressure injury that progressed from a Stage 2 ulcer on the left hip/trochanter to a Stage 3 ulcer. The care plan included a pressure reduction mattress, a pressure relieving cushion when up in the wheelchair, and reminders to reposition, but it did not include interventions or education for offloading the left hip or addressing the resident’s bed size concerns. Observations showed no offloading wedge or positioning pillows in the room, and the bed extender that was later placed at the foot of the bed did not extend the air mattress or provide additional support for the resident’s legs. Staff later acknowledged the bed and mattress were standard length and that the resident would benefit from a longer bedframe and air mattress.
Penalty
Resources
Below are regulatory guidelines relevant to this citation:
Trusted data from CMS and state health departments
Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release July 29, 2026) and official state health department websites — never guesswork.
In your survey window? See what surveyors are citing.
The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.