F0759 F759: Ensure medication error rates are not 5 percent or greater.
D

Medication Administration Errors Exceeded Allowed Rate

Great Lakes Rehabilitation CenterSaginaw, Michigan Survey Completed on 01-14-2026

Summary

The facility failed to administer medications per standards of practice for two residents during medication administration observations, resulting in a medication error rate of 6.67 percent. For one resident, a nurse prepared a Heparin injection using a 3 cc syringe with a 1-inch needle and initially identified the medication as IM before correcting to subcutaneous. Outside the resident’s room, the nurse questioned the required needle size and the physician’s order, then clarified the order in the electronic medical record and obtained a smaller syringe and appropriate needle before administering the Heparin subcutaneously. The resident’s record showed an order for Heparin Sodium (Porcine) Injection Solution 5000 UNIT/ML, inject 1 ml subcutaneously. For another resident, a nurse gathered morning medications and crushed Potassium chloride 30 milliequivalent before administering it orally. The nurse stated the resident had recently been sent to the emergency room and was being checked for a change in condition. When later questioned, the nurse acknowledged the Potassium should not have been crushed because it was extended release and stated the physician had not been called about the crushed administration. The pharmacist later stated the Potassium chloride ER should not be crushed and could be switched to liquid. The facility policy stated medications shall be administered safely and as prescribed, and the medication administrator must check the label three times to verify the right resident, medication, dosage, time, and route.

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0759 citations
Medication Given Outside Ordered Vital Sign Parameters
D
F0759 F759: Ensure medication error rates are not 5 percent or greater.
Short Summary

Medication error rate exceeded the required threshold when an RN administered Amlodipine and Losartan Potassium to a resident despite a pulse below the ordered hold parameter of 60. The resident had HTN, hypotension, Parkinsonism, and moderate cognitive impairment. The RN acknowledged the error, and the DON and ADM stated they were unaware the physician orders had not been followed until after the observation.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Medication Administration Errors Exceeded Allowed Rate
D
F0759 F759: Ensure medication error rates are not 5 percent or greater.
Short Summary

Medication Administration Errors Exceeded Allowed Rate: The facility had a 5% med error rate based on 2 errors in 40 opportunities. During observation, an MA gave one resident guaifenesin 400 mg instead of the ordered 600 mg dose, and gave another resident cranberry 450 mg instead of the ordered 500 mg dose. The MA stated she caught one error but missed the other, while the DON said he was unsure when staff last received med admin training and the ADM expected staff to verify the correct dose before giving meds.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Medication Administration Timing Error Exceeded Allowed Error Rate
D
F0759 F759: Ensure medication error rates are not 5 percent or greater.
Short Summary

An LPN administered nine oral medications to a resident 1 hour and 36 minutes late, despite provider orders specifying an 8:00 AM administration time. Surveyors found nine errors in 31 medication administration opportunities, and the DON stated the expected medication window was 1 hour before and 1 hour after the ordered time.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Medication Administration Times Not Followed
E
F0759 F759: Ensure medication error rates are not 5 percent or greater.
Short Summary

Medication administration error rates exceeded the allowed threshold when an MA gave scheduled meds to two residents after the ordered 9:00 a.m. time. One resident had dementia, HTN, atherosclerosis, and clotting-related diagnoses and received acetaminophen, warfarin, atenolol, and enalapril late; another resident with HTN, depression, anxiety, and chronic pain received amlodipine, duloxetine, gabapentin, and Gemtesa late. Staff interviews confirmed expectations for timely administration, and the facility policy reviewed did not include a specific medication-time policy.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Medication Error Rate Exceeded Allowed Threshold
D
F0759 F759: Ensure medication error rates are not 5 percent or greater.
Short Summary

Medication Error Rate Exceeded Allowed Threshold: An LPN prepared and nearly administered two incorrect medications for a resident, including a BP medication without checking the resident’s BP despite a hold parameter and Meclizine at 25 mg instead of the ordered 12.5 mg. The survey found the facility’s medication error rate was 8% (2 errors out of 25 opportunities), exceeding the required rate of less than 5%.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Medication Error Rate Exceeded Threshold
D
F0759 F759: Ensure medication error rates are not 5 percent or greater.
Short Summary

Medication error rate exceeded the allowed threshold after surveyors found 3 errors in 25 opportunities. An RN gave insulin at an inappropriate site for a resident with DM and severe cognitive impairment, and a Med Aide failed to administer ordered eye drops and did not give the full ordered dose of a laxative for another resident with severe cognitive impairment. The DON stated staff were expected to audit and replenish carts and notify nursing if OTC meds were needed.

Inspection fine: $26,180
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Citation search

Search every citation & Plan of Correction

Go to search
Citation watch

Track new serious citations across Michigan

Get a heads-up on the newest immediate-jeopardy (J–L) citations in Michigan — where surveyors are focused right now.

Free · about one email a month

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release July 29, 2026) and official state health department websites — never guesswork.

In your survey window? See what surveyors are citing.

The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.

Get the Survey-Prep Report
An unhandled error has occurred. Reload 🗙