F0690 F690: Provide appropriate care for residents who are continent or incontinent of bowel/bladder, appropriate catheter care, and appropriate care to prevent urinary tract infections.
D

Failure to Secure and Cover Foley Catheters

Hutchinson Operator, LlcHutchinson, Kansas Survey Completed on 01-29-2026

Summary

The facility failed to provide adequate catheter-related care for three residents with indwelling urinary catheters by not securing catheter tubing to prevent pulling or dislodgement and by not keeping urine collection bags covered and sanitary. The facility census was 42 residents, and the sample included 12 residents, with three residents reviewed for urinary catheters. The report identified these failures for R4, R7, and R21 based on observation, interview, and record review. R4 had diagnoses including bladder dysfunction and inflammatory reaction due to an indwelling urethral catheter, intact cognition, and dependence on staff for most ADLs. Her care plan directed staff to provide foley catheter care, change the catheter as needed, observe tubing for kinks, and keep the catheter below bladder level. During observation, her catheter tubing was hanging freely without being secured to her skin, and later her urine collection bag was hanging on a garbage can without a cover and touching the floor. A CNA stated there were no securement devices available, and R4 reported she was being treated for another possible UTI. R7 had diagnoses of urinary retention and anxiety, intact cognition, and dependence on staff for toileting hygiene, showers, and dressing. Her care plan directed foley catheter care and keeping the catheter below bladder level, and her record noted a history of frequent UTI with resistant bacteria. During observation, her room smelled strongly of urine, her catheter tubing had no securement device, and her catheter bag was not covered. R21 had diagnoses of sepsis and neuromuscular dysfunction of the bladder, intact cognition, and dependence on staff for toileting hygiene, showers, and personal hygiene. Her care plan directed foley catheter care and keeping the catheter below bladder level. During observation, her urine collection bag was not covered and was positioned toward the doorway, and she reported she had no anchor or securement device, was lucky if she got catheter care, and had to ask for her catheter to be cleaned. An administrative nurse stated staff were expected to apply securement devices and cover catheter drainage bags with a dignity bag, and the facility policy required both covering the urine bag and securing the catheter with a leg strap.

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0690 citations
Catheter Bag Left on Floor Beside Bed
D
F0690 F690: Provide appropriate care for residents who are continent or incontinent of bowel/bladder, appropriate catheter care, and appropriate care to prevent urinary tract infections.
Short Summary

A resident with an indwelling urinary catheter, ordered for urinary retention related to hydronephrosis, was observed in bed with the catheter collection bag lying flat on the floor beside the bed and containing urine. The resident said an aide had helped her back to bed after breakfast, and one aide confirmed she assisted the resident but forgot to hang the bag from the bed frame as she normally would. The DON and Administrator stated catheter bags were expected to be kept off the floor.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Catheter Care and Securement Not Maintained
E
F0690 F690: Provide appropriate care for residents who are continent or incontinent of bowel/bladder, appropriate catheter care, and appropriate care to prevent urinary tract infections.
Short Summary

Catheter care and securement were not maintained for three residents with indwelling catheters. One resident's drainage bag was found lying in bed with tubing under the leg and no strap in place, another resident's tubing was under the leg with no strap present, and a third resident received catheter care from a CNA who cleansed the catheter using a back-and-forth motion and reused the same wipe instead of cleaning away from the penis in one direction. The DON and other staff stated the bag should be below the bladder, the strap should secure the tubing, and catheter care should be performed using proper technique.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Catheter Drainage Bag Positioned Above Bladder Level
D
F0690 F690: Provide appropriate care for residents who are continent or incontinent of bowel/bladder, appropriate catheter care, and appropriate care to prevent urinary tract infections.
Short Summary

A resident with a catheter for neurogenic bladder, impaired cognition, and total bowel/bladder incontinence had a catheter drainage bag repeatedly observed hooked on a wheelchair arm rest above bladder level. The tubing contained urine that had not drained down, the resident tried to move the tubing to drain it, and staff interviews confirmed the bag should have been positioned below the bladder; one RN also stated the resident was on antibiotics for a bladder infection.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Foley Bag Placed at Bladder Level During Incontinent Care
D
F0690 F690: Provide appropriate care for residents who are continent or incontinent of bowel/bladder, appropriate catheter care, and appropriate care to prevent urinary tract infections.
Short Summary

Foley Bag Placed at Bladder Level During Care: A resident with an indwelling Foley catheter, severe cognitive impairment, and obstructive uropathy had his drainage bag emptied and then placed on the bed at bladder level during perineal care. Observation showed urine moving back toward the catheter insertion site while the resident was repositioned. Staff interviews confirmed the bag should remain below the bladder at all times, and the facility policy required the drainage bag to be positioned lower than the bladder to prevent backflow.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Unsecured Foley Catheter and Incomplete Incontinent Care
D
F0690 F690: Provide appropriate care for residents who are continent or incontinent of bowel/bladder, appropriate catheter care, and appropriate care to prevent urinary tract infections.
Short Summary

A resident with a Foley catheter was observed with the tubing not secured to the leg during care, and staff acknowledged it should have been secured to prevent pulling and injury. In a separate observation, two CNAs provided incontinent care to another resident with bowel incontinence and an indwelling catheter but did not clean the inner thighs or right buttock area before applying a clean brief, despite the care plan and facility policy requiring thorough perineal cleansing.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Catheter Bag and Tubing Left in Contact With Floor
D
F0690 F690: Provide appropriate care for residents who are continent or incontinent of bowel/bladder, appropriate catheter care, and appropriate care to prevent urinary tract infections.
Short Summary

A resident with a catheter was observed with the catheter bag and tubing exposed outside the privacy bag and resting directly on the floor, and the resident moved the wheelchair over the bag. An RN later confirmed that catheter bag and tubing should not be in direct contact with the floor.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Citation search

Search every citation & Plan of Correction

Go to search
Citation watch

Track new serious citations across Kansas

Get a heads-up on the newest immediate-jeopardy (J–L) citations in Kansas — where surveyors are focused right now.

Free · about one email a month

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release July 29, 2026) and official state health department websites — never guesswork.

In your survey window? See what surveyors are citing.

The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.

Get the Survey-Prep Report
An unhandled error has occurred. Reload 🗙