F0686 F686: Provide appropriate pressure ulcer care and prevent new ulcers from developing.
D

Air Mattress Pump Not Functioning Properly for At-Risk Resident

Norwood CrossingChicago, Illinois Survey Completed on 07-25-2025

Summary

Failure to provide appropriate pressure ulcer care occurred when the facility did not ensure a pressure relieving device was functioning properly for one resident who was at risk for pressure ulcers. R20 was observed lying in bed asleep and in no apparent distress, with an air loss mattress and pump in place. At the time of observation, the pump display screen was dark, no items were displayed, and no sound was heard from the pump. R20's mattress appeared and felt slightly flat and lumpy. During the observation, V15 attempted to press the lock button and on/off button on the pump, but nothing appeared on the screen. V6 then pressed several buttons and found the screen still did not appear until a hose/tube was pulled out and reinserted more tightly, after which the pump screen lit up and sound was heard. The resident's care plan documented risk for pressure ulcer/skin breakdown due to impaired mobility, right pelvic fracture, and incontinence, and the active physician order set included an air mattress dated 02/17/2023. The manufacturer manual provided by the facility stated that if the controller is inoperable, the mattress may feel lumpy and the solution is to make sure the controller is plugged in and turned on.

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0686 citations
Failure to Reposition Resident With Stage 4 Pressure Ulcer
D
F0686 F686: Provide appropriate pressure ulcer care and prevent new ulcers from developing.
Short Summary

Failure to Reposition Resident With Stage 4 Pressure Ulcer: A resident with diabetes, CAD, HTN, and a stage 4 coccyx pressure ulcer was assessed as needing repositioning every 2 hours, but during prolonged observation staff did not offer repositioning while the resident remained in the same position in bed. The care plan called for turning and repositioning per tissue tolerance, but the bedside Kardex did not specify how often to reposition. When the issue was identified, RN and the ADON turned the resident and noted blanchable redness on the left buttocks and upper thigh.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Provide Ordered Wound Care for Pressure Injury
D
F0686 F686: Provide appropriate pressure ulcer care and prevent new ulcers from developing.
Short Summary

Failure to provide ordered wound care for a resident with an unstageable pressure injury. The resident had chronic venous insufficiency and cellulitis, and the MDS showed the resident was cognitively intact with a pressure ulcer present on admission. A physician ordered xeroform gauze, Dakin's-soaked Kerlix packing, and an ABD pad twice daily, but observations found the wound without the ordered dressing and packing, then later with a soiled dressing and protruding packing. An LPN confirmed the dressing was soiled and undated/untimed, and the ADON acknowledged the findings.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Pressure ulcer prevention and wound care failures
G
F0686 F686: Provide appropriate pressure ulcer care and prevent new ulcers from developing.
Short Summary

Pressure ulcer prevention and wound care failures were identified for multiple residents. A resident with immobility and diabetes developed a facility-acquired sacral wound that progressed to an infected stage 4 ulcer requiring hospitalization and debridement, while surveyors observed missed wound vac documentation, stool-contaminated dressings, improper offloading, low air loss mattresses on static mode or incorrect weight settings, missing heel protectors, and a wheelchair resident without a pressure-relieving cushion.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Clean and Monitor a Pressure Injury
D
F0686 F686: Provide appropriate pressure ulcer care and prevent new ulcers from developing.
Short Summary

Failure to Clean and Monitor a Pressure Injury: The facility failed to promote healing of a resident’s unstageable DTI to the right ischium. During wound care, the DON applied treatment without cleaning the wound first, despite staff and the wound physician stating that cleansing with saline or wound cleanser was appropriate. The record also lacked weekly nursing assessments documenting the wound’s location, stage, size, and description, and the facility relied on intermittent wound physician visits that were missed when the resident was at dialysis or out of the facility.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Measure and Offload a Right Heel Pressure Injury
D
F0686 F686: Provide appropriate pressure ulcer care and prevent new ulcers from developing.
Short Summary

Failure to Measure and Offload a Right Heel Pressure Injury: A resident with DM, PVD, and a history of skin breakdown developed a right heel PI that was identified as a deep tissue injury and later progressed to stage 2 and then unstageable. Staff did not obtain wound measurements for about two weeks after discovery, several skin reviews lacked wound details, and surveyors observed the resident without ordered offloading boots in the recliner and wheelchair even though staff said the boots were to be worn at all times.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Prevent and Treat Pressure Ulcers
J
F0686 F686: Provide appropriate pressure ulcer care and prevent new ulcers from developing.
Short Summary

Failure to Prevent and Treat Pressure Ulcers: A resident with impaired cognition, total ADL dependence, incontinence, and high Braden risk developed worsening sacral and heel pressure injuries after staff did not consistently implement wound prevention measures or recognize the change in condition when sacral redness was first noted. The wound progressed to an infected stage IV sacral ulcer with foul odor, drainage, altered mental status, and hospital transfer; interviews and records also showed the wound was not consistently tracked or care planned, and the resident’s skin breakdown was not promptly escalated.

Inspection fine: $38,284
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Citation search

Search every citation & Plan of Correction

Go to search
Citation watch

Track new serious citations across Illinois

Get a heads-up on the newest immediate-jeopardy (J–L) citations in Illinois — where surveyors are focused right now.

Free · about one email a month

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release August 26, 2026) and official state health department websites — never guesswork.

In your survey window? See what surveyors are citing.

The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.

Get the Survey-Prep Report
An unhandled error has occurred. Reload 🗙

Connection lost — reconnecting… We couldn't reconnect automatically. Please reload the page to continue.