Staff Competency Deficiencies in CPR and Emergency Equipment Use
Summary
The facility failed to ensure that four of five staff members observed and interviewed demonstrated the competencies needed to respond to an emergency and perform CPR in accordance with facility policy and CPR guidance. During a concurrent observation and interview, CNA 1 stated that if a resident was found unresponsive, he would check chest rise and a pulse on the neck for two minutes before starting chest compressions, and he did not know the correct compression rate. CNA 2 stated that she would check for chest rise and a pulse for thirty seconds before starting CPR and was not sure how fast compressions should be performed. CNA 2 was also observed checking the carotid pulse with two fingers before performing compressions. RN 1 was observed reviewing the emergency crash cart but stated she had not checked it that day. When asked to demonstrate emergency equipment use, RN 1 stated she did not know where the adult oxygen masks, suction catheters, short and long connective tubing, CPR mask/shield, or PPE were located in the crash cart. She also stated she did not know how to connect, turn on, or determine whether the suction machine was operable, and she did not know how to check whether the oxygen tank was operable or contained oxygen. RN 1 further stated she did not know what pressure the suction machine should be set at and gave an incorrect CPR compression rate and depth. RN 2 was observed checking the crash cart and stated she did not know the location of the suction catheters and CPR masks/shields within the cart. She stated the suction device should be set at 200-300 mmHg, while the facility policy for suctioning the upper airway indicated a negative pressure of 10-15 mmHg. The DSD also failed to demonstrate proficient chest compressions, stating the count rate as 1 one thousand through 30 one thousand, and stated that during mock code drills staff performed 30 compressions to 2 breaths using an ambu-bag for two minutes. The DSD stated there was no documented evidence that the competencies and understanding of the LNs and CNAs were evaluated for the training provided during the mock Code Blue drills.
Penalty
Resources
Below are regulatory guidelines relevant to this citation:
Trusted data from CMS and state health departments
Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release July 29, 2026) and official state health department websites — never guesswork.
In your survey window? See what surveyors are citing.
The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.