F0880 F880: Provide and implement an infection prevention and control program.
E

Infection Prevention and Control Deficiencies

South Marin Health & Wellness CenterGreenbrae, California Survey Completed on 12-04-2025

Summary

Enhanced Barrier Protection was not implemented for a resident with a thoracic surgical wound being treated with negative pressure wound therapy. The resident’s face sheet showed an admission in 11/2025 with a diagnosis of infection and inflammatory infection due to an internal device of the spine. The physician ordered the wound vac on 11/19/25 for the thoracic surgical wound. During a 12/01/2025 observation, the resident stated nurses performed wound treatment, but no EBP signage was posted at the door and staff did not wear gowns during wound treatment, brief changes, dressing, or transfers. During interviews, the LN verified the resident had a surgical wound on the back being treated with a wound vac and was not placed on EBP. The LN stated he did not wear a gown when treating the wound and stated residents on wound vac should be placed on EBP for resident and staff safety. The IP also verified the resident had a wound vac but was not placed on EBP and stated this was an oversight. The DON verified residents with wound vac should be placed on EBP per facility policy and confirmed the resident should have been on EBP. The facility’s EBP policy stated EBP was indicated for residents with wounds and/or indwelling medical devices regardless of MDRO colonization. The facility did not follow the manufacturer’s recommended contact time when sanitizing the glucometer before blood sugar checks for three residents with diabetes and chronic kidney disease. During observations, an LN used a Super Sani-Cloth purple top germicidal wipe on the glucometer and used it after about 70 seconds for one resident, and for another resident inserted the test strip while the glucometer was still wet without waiting for the 2-minute contact time. The LN later stated she typically waited only 1 to 3 seconds and confirmed she was not following the 2-minute contact time. The IP verified the glucometer required a 2-minute contact time with the wipe solution before use, and the product information stated the wipe was effective against microorganisms in 2 minutes. Staff also failed to perform hand hygiene and glove changes during resident care. A CNA was observed providing perineal care to a resident, disposing of the soiled brief, adjusting the waste bin lining, and then applying a clean brief without changing gloves. The CNA stated she should have changed gloves between the soiled and clean brief. During wound care for the same resident, an LN removed the dressing, cleansed the wound, removed gloves, and then put on new gloves without performing hand hygiene before applying medication and covering the wound. The LN confirmed he had not performed hand hygiene before donning the new gloves. The DON stated staff should perform hand hygiene before tasks and before putting on new gloves, and that after removing wound dressing staff should remove gloves, perform hand hygiene, and put on new gloves. The facility also did not ensure adequate monitoring for Legionella bacteria in the water system. The IP stated the facility only called the local health department if Legionella was suspected, and the Administrator stated the facility did not test for Legionella in the water system. The Maintenance Director stated he monitored water temperatures in residents’ rooms and bathrooms, and the facility’s Legionella water management policy described a program to identify areas where Legionella can grow and spread and to monitor control limits or parameters. The water flow diagram reviewed did not identify markers in the water system where Legionella bacteria can grow and spread or where parameters may be monitored.

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0880 citations
Infection Control Practices Not Consistently Implemented for Resident Evaluated for C. difficile
D
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

A resident being evaluated for C. difficile was not consistently managed under the correct contact-enteric precautions. Staff gave care with incomplete understanding of the precautions, the room signage did not clearly identify the needed disinfectant or contact time, bleach wipes were not always available, and staff were observed missing hand hygiene and handling items under PPE during care.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Use EBP PPE During Wound Care
D
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

Failure to Use EBP PPE During Wound Care: A resident with a wound and severely impaired cognition was receiving ordered wound care when the DON and ADON entered the room, washed hands, and donned gloves but did not wear gowns before starting care. EBP signage and PPE were present at the bedside, and both leaders later stated they forgot to put on gowns even though the resident was on EBP for an open wound and the facility policy required gown and glove use for wound care.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Follow Enhanced Barrier Precautions and Hand Hygiene During Resident Care
D
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

Staff failed to consistently follow EBP and hand hygiene for two residents who required high-contact care. One resident with an indwelling catheter and cognitive impairment did not have EBP followed during transfers, clothing removal, and pericare, and another resident with a suprapubic catheter and multiple pressure ulcers had staff wear PPE incorrectly, remove PPE in the room without hand hygiene, and continue care after emptying the catheter bag without changing gloves or cleaning hands. Interviews confirmed staff were expected to use gowns, gloves, and hand hygiene for these tasks.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Use Required PPE for Resident on Contact Precautions
D
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

A resident on Contact Precautions for active C. difficile infection was not consistently protected by required PPE. Although signage outside the room directed all entrants to wear a gown and gloves, an RN entered the room with medications without either item and touched the bedside table and door surface. The resident stated staff did not always wear gowns, and the DON confirmed staff were expected to wear a gown and gloves when entering the room while precautions were in place.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Infection Control Lapses During Incontinence and Ostomy Care
E
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

A facility failed to maintain infection control during care for two residents. During incontinence care, a CNA removed gloves and applied clean gloves without hand hygiene before placing a clean brief on a resident who was dependent for toileting hygiene and always incontinent. During ostomy care, an LVN handled a resident’s colostomy, wiped stool from the stoma, and continued care without removing soiled gloves, sanitizing hands, or putting on clean gloves. The DON stated staff were expected to perform hand hygiene between glove changes.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Infection Control Failures During Incontinent Care
D
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

Infection Control Failures During Incontinent Care: Two residents were observed receiving incontinent care with multiple infection control lapses. A CNA did not perform hand hygiene between glove changes or after glove removal while caring for one resident, and another CNA did not wash hands before care, changed nothing between dirty and clean tasks, touched clean items with dirty gloves, placed soiled linens on the floor, and handled dirty linens with bare hands after glove removal. The DON stated hand hygiene, glove changes, and proper handling of soiled linens were required, and facility policies reflected those practices.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Citation search

Search every citation & Plan of Correction

Go to search
Citation watch

Track new serious citations across California

Get a heads-up on the newest immediate-jeopardy (J–L) citations in California — where surveyors are focused right now.

Free · about one email a month

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release October 8, 2026) and official state health department websites — never guesswork.

In your survey window? See what surveyors are citing.

The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.

Get the Survey-Prep Report
An unhandled error has occurred. Reload 🗙

Connection lost — reconnecting… We couldn't reconnect automatically. Please reload the page to continue.