Food Storage, Drainage, and Dishwasher Sanitizing Temperature Deficiencies
Summary
The facility failed to ensure food and equipment were stored at least 6 inches above the floor. During kitchen observations, a pot and pan shelving rack and a shelf in the walk-in cooler were seen too low to the floor. The Maintenance Supervisor measured the walk-in cooler shelf at 2 3/4 inches from the floor, and measured the bottom of the pot and pan shelving rack at 3 inches on one end and 4 inches on the other end. The Maintenance Supervisor stated the shelf was not far enough away from the floor, could not be seen or cleaned under, and rodents could hide there. The Certified Dietary Manager and the Registered Dietitian both identified the concern with the shelving being less than 6 inches off the floor as inadequate room to clean underneath and, for the cooler shelf, inadequate air flow under it. The facility policy for Food and Equipment Storage stated that food and equipment should be stored at a minimum of 6 inches above the ground, and the FDA Food Code required food and cleaned equipment and utensils to be stored at least 6 inches above the floor. The facility also failed to maintain proper separation for a drainpipe from the three-compartment sink. During observation, one of the sink drains was seen resting inside the floor drain. The Maintenance Supervisor stated the drainpipe came from the rinse sink, that a strap had broken, and that the drainpipe was in the floor drain. He said waste water could come back into the sink from the floor drain. The CDM and RD both identified the issue as a lack of air gap and a potential backflow or cross connection. In addition, the dishwasher final rinse temperature exceeded the manufacturer’s specified range and the FDA Food Code limit. The dishwasher manual required a final rinse temperature between 180 and 195 degrees F, while the FDA Food Code stated the sanitizing rinse may not be more than 194 degrees F. During observation, the dishwasher final rinse was seen at 198 degrees F, and the Maintenance Supervisor confirmed the temperature could be adjusted. The CDM stated the normal final rinse temperature was between 180 and 198 degrees F, and the RD stated the concern with the temperature being too high was the potential flash evaporation of the final rinse water.
Penalty
Resources
Below are regulatory guidelines relevant to this citation:
Trusted data from CMS and state health departments
Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release October 8, 2026) and official state health department websites — never guesswork.
In your survey window? See what surveyors are citing.
The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.