Respiratory Equipment Not Dated, Changed, or Stored Properly
Summary
The facility failed to change and date oxygen tubing and supplies as ordered for residents receiving respiratory care, and failed to store respiratory equipment in a safe and sanitary manner. Resident #44 had diagnoses including COPD, pulmonary embolism, CHF, CKD, and chronic respiratory failure, and the care plan directed oxygen use, aerosol treatments, respiratory assessments, and monitoring. The physician orders required weekly cleaning of the oxygen concentrator filter and weekly changes of the oxygen tubing, cannula, and mask, but the MAR/TAR showed no documented evidence that the nasal cannula or humidifier bottle had been changed weekly. During observation, the resident’s oxygen nasal cannula and humidifier bottle were not dated, and the humidifier bottle was empty; an RN confirmed the tubing had no date and there was no documented evidence it had been changed since admission. Resident #38 had diagnoses including CHF, diabetes mellitus, hypothyroidism, atrial fibrillation, depression, and osteomyelitis of the lumbar vertebrae, and the care plan included oxygen therapy with weekly changes of oxygen tubing, mask, and cannula. The physician orders also required weekly filter changes on the oxygen concentrator and oxygen saturation checks every shift while on oxygen. On observation, the resident’s oxygen nasal cannula and humidifier bottle were not dated, and the humidifier bottle was empty; an RN verified the items were undated and empty. Resident #71 had diagnoses including paralytic syndrome, COPD, asthma, GERD, osteoporosis, pulmonary heart disease, diaphragmatic hernia, allergic rhinitis, dysphagia, and peripheral vascular disease, and received budesonide via nebulizer. The physician order required nebulizer tubing, cannula, and mask to be changed weekly. The nebulizer tubing and mask were observed lying in an open plastic box on a brown paper towel with no visible date, and an RN confirmed the supplies were undated. Resident #82 had COPD, type II diabetes mellitus, CHF, and obstructive sleep apnea, with orders for continuous oxygen and weekly changes of oxygen and nebulizer tubing/mask/cannula. The TAR did not document an oxygen tubing change on one scheduled date, and the resident was observed with an undated empty humidifier bottle, no date on the oxygen tubing, and an uncovered nebulizer mask lying on the bed with tubing labeled with a prior date; an LPN confirmed the humidifier bottle was empty, the oxygen tubing was not dated, and the nebulizer mask was uncovered on the bed.
Penalty
Resources
Below are regulatory guidelines relevant to this citation:
Trusted data from CMS and state health departments
Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release July 29, 2026) and official state health department websites — never guesswork.
In your survey window? See what surveyors are citing.
The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.