Kitchen sanitation and equipment maintenance deficiencies
Summary
The facility failed to maintain food service equipment and kitchen areas in sanitary condition during the initial kitchen tour with the Dietary Director. The hand sink in the ware washing area was obstructed and nonfunctional, the hand sink was attached to an unsealed plywood wall, and the high-temperature dishwasher was visibly stained and rusted. The dishwasher drainpipes discharged directly into the floor sink without an air gap, the food waste grinder was clogging the above-ground grease trap interceptors, and the two grease trap interceptors were overfilled and corroded. The 3-compartment sink gooseneck faucet was leaking, one drain line was leaking gray water onto the floor, and required temperature and sanitizing logs were missing for several days. Multiple tiles were missing or damaged around the underground grease trap interceptor, the wet vacuum was unclean, and several food service areas, including the tray line, cookline, food prep sink area, ice machine area, and walk-in refrigerator/freezer, were observed to be unclean or in disrepair. Additional observations included a chef’s knife stored between the hot and cold lever handles of the in-counter prep sink, a leaking drain line beneath that sink, grease buildup on the stove overshelf, unclean walls behind and beneath cooking equipment, a burned-out hood light, and a reach-in refrigerator that was partially blocked by a storage rack and had a damaged door gasket. The food prep sink drainpipes were unclean and missing a floor drain cover, the deli slicer was unclean, the ice machine drain line discharged directly into the floor sink without an air gap, and the ice machine deflector shield and scoop holder were unclean. In the walk-in refrigerator/freezer area, a toaster oven was placed on top of a microwave near the walk-in door, the walk-in gasket was missing, shelving and surfaces were unclean, compressor fans and covers were unclean, and dunnage racks were lined with torn cardboard boxes with dirt and debris buildup. During the second tour with the Maintenance Director and Regional Director of Operations, the surveyor also reviewed backflow prevention devices on waterlines for equipment such as the ice machine, coffee maker, juice machine, and mop sink, and observed that the canopy hood ventilation system was not sufficiently pulling air underneath the cookline when smoke was used to demonstrate airflow. On 9/30/2025 at 1:10 AM, surveyors observed the ware washing area was inaccessible during lunch preparation and service because a contractor was replacing two above-ground grease trap interceptors and the dishwasher drainpipes. The ware washing area floors were soiled with grease and sewage water that employees tracked throughout the kitchen, and a foul sewage odor permeated the kitchen. The contractor was instructed to stop remaining dishwasher pumping repairs to prevent potential cross-contamination.
Penalty
Resources
Below are regulatory guidelines relevant to this citation:
Trusted data from CMS and state health departments
Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release August 26, 2026) and official state health department websites — never guesswork.
In your survey window? See what surveyors are citing.
The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.