Failure to Monitor Refrigerator and Dishwasher Temperatures
Summary
The facility failed to ensure that refrigerator and freezer temperatures in three resident kitchenette nourishment rooms were identified and reported when they were out of range. During a kitchen tour, the Director of Dining Services (DDS) stated that cooks completed the daily temperature logs for the kitchen refrigerators and the resident unit kitchenette refrigerators, and that the Infection Control Nurse also verified expiration dates. However, review of the nourishment room refrigerator/freezer logs showed repeated out-of-range temperatures in the first-floor, second-floor, and ground-floor units across June and July 2025, with the logs instructing staff to report all temperatures out of range. The DDS stated he was not made aware of the abnormal temperatures recorded on these logs, and one cook later stated she took low readings twice, adjusted the refrigerator dial herself, and did not notify anyone. Observations of the resident kitchenette refrigerators showed temperatures outside the acceptable range while resident food and beverages were stored inside. The first-floor refrigerator was observed at 38 degrees F with multiple resident-labeled and resident food items inside, and the second-floor refrigerator was observed at 30 degrees F with yogurt, thickened liquids, milk, juice, sandwiches, salad, and frozen items stored inside. The ground-floor log also showed multiple out-of-range temperatures and missing entries. One staff member stated she did nothing when she obtained out-of-range temperatures and was confused by the log instructions. The facility also failed to identify low temperatures during a dishwasher cycle. During observation, the dishwasher wash cycle measured 129 degrees F and the rinse cycle measured 143 degrees F, below the stated required temperatures of 160 degrees F and 180 degrees F. Two dietary aides continued processing dishes and plate covers without identifying the low temperatures or checking the cycle temperatures. The DDS stated the staff were not aware to monitor the temperatures during the cycle, and there was no written policy for checking dishwasher temperatures between wash cycles; the facility relied on verbal instruction and training.
Penalty
Resources
Below are regulatory guidelines relevant to this citation:
Trusted data from CMS and state health departments
Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release October 8, 2026) and official state health department websites — never guesswork.
In your survey window? See what surveyors are citing.
The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.