F0880 F880: Provide and implement an infection prevention and control program.
E

Infection control practices not followed for oxygen tubing and shared equipment

Arlington Gardens Care CenterRiverside, California Survey Completed on 01-08-2026

Summary

The facility failed to ensure infection control practices were followed for four residents reviewed for infection control practices. For Resident 125, who was admitted on December 28, 2025, with diagnoses including left hip joint replacement surgery and who had a physician order for continuous oxygen at 2 LPM via nasal cannula, the resident was observed on January 6, 2026, receiving oxygen through nasal cannula tubing dated December 29, 2025. The assigned LVN stated the tubing should have been changed every Sunday, and the DON confirmed the facility process was to change respiratory tubing weekly every Sunday. The facility policy for prevention of infection with respiratory equipment stated the oxygen cannula and tubing should be changed every seven days or as needed. For Resident 36, LVN 1 was observed checking blood sugar with an Assure Platinum glucometer and placing the used device on top of the medication cart without cleaning or disinfecting it afterward. LVN 1 stated he had wiped the glucometer with an alcohol wipe before checking Resident 36's blood sugar, and later stated he had used the same glucometer on Resident 103 and then Resident 36, using alcohol wipes rather than the bleach wipes required by the facility. The glucometer manual stated the meter should be cleaned and disinfected after use on each patient, and the facility policy required blood glucose meters intended for reuse to be cleaned and disinfected between residents according to the manufacturer's instructions. For Residents 36, 111, and 69, LVN 1 used the same shared blood pressure cuff on multiple residents and wiped it with alcohol wipes between uses. During observations, the cuff was used on Resident 36, then on Resident 111, and then on Resident 69, with alcohol wipes used before use on the later residents. LVN 1, LVN 3, LVN 6, and the Infection Preventionist stated bleach wipes were supposed to be used for the glucometer and BP cuff between residents, and the Infection Preventionist verified that alcohol wipes were not appropriate for sanitizing shared equipment between residents. The facility policy on cleaning and disinfection of environmental surfaces stated manufacturers' instructions would be followed for proper use of disinfecting products.

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0880 citations
Failure to Follow EBP and Hand Hygiene During Incontinence Care
D
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

Failure to Follow EBP and Hand Hygiene During Incontinence Care: A resident with a catheter, hospice care, heart failure, and a lumbar compression fracture had a care plan for EBP requiring gown and gloves for high-contact care. During incontinence care, a CNA provided care without a gown, touched the bed linens, curtain, and gown with a uniform, and handled stool-soiled items without changing gloves or performing hand hygiene. A second CNA assisted with turning and wiping stool but changed gloves without hand hygiene; an RN later stated the PPE and hand hygiene used were not appropriate.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Infection Control and Enhanced Barrier Precautions Not Used During Wound Care
E
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

Infection Control and EBP Not Used During Wound Care Three residents with open wounds received wound care from RNs without PPE, and there was no PPE or precaution signage outside their rooms. The nurses and leadership stated the residents were not on EBP because the wounds were not infected or were considered simple dressings, even though the facility policy required gown and glove use for wound care involving any skin opening requiring a dressing and identified complex/infected wounds as EBP indications.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Follow EBP During Urinary Catheter Care
D
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

Failure to follow EBP during urinary catheter care: an LPN provided catheter care to a resident without wearing the required PPE gown, despite an EBP sign posted on the room door and gowns being available at the entrance. The nurse stated he wore a gown for contact precautions but not for EBP and was unaware a gown was required for catheter care; the IP, DON, and Administrator all stated a gown was expected for this high-contact activity.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Incomplete TB Testing on Admission
D
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

A resident admitted for skilled nursing services did not have documented TB testing completed on admission. A T-spot was later drawn, but there was no record that the specimen was sent to the lab or that results were obtained. The DON stated the facility missed the resident during TB audit checks and that the sample was not processed because the lab form was not sent with it, despite the facility policy requiring TB screening and testing within 72 hours of admission.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Infection Control Lapses With PEG Medication Administration and Oxygen Tubing Storage
D
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

The facility failed to maintain infection control for two residents. An RN did not sanitize hands between glove changes while administering medication via a resident’s PEG tube, despite the resident being on EBP and having a care plan for tube feeding and meds via PEG. In another instance, a resident with respiratory failure had oxygen tubing left unbagged when not in use, even though staff stated it should be bagged to prevent contamination.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Use PPE in Contact Isolation Room
D
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

A resident with klebsiella, a UTI, MDR organism status, an indwelling urinary catheter, and IV access was on contact precautions with signage at the door requiring hand hygiene, gown, and gloves before entry. A CNA entered the room and answered the call light without PPE, and later stated she only used PPE for catheter care. The charge nurse and DON stated staff were expected to wear PPE whenever entering the contact isolation room.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Citation search

Search every citation & Plan of Correction

Go to search
Citation watch

Track new serious citations across California

Get a heads-up on the newest immediate-jeopardy (J–L) citations in California — where surveyors are focused right now.

Free · about one email a month

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release July 29, 2026) and official state health department websites — never guesswork.

In your survey window? See what surveyors are citing.

The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.

Get the Survey-Prep Report
An unhandled error has occurred. Reload 🗙