F0880 F880: Provide and implement an infection prevention and control program.
E

Failure to Implement Transmission-Based Precautions

Ignite Medical Resort San Antonio, LlcSan Antonio, Texas Survey Completed on 12-08-2025

Summary

The facility failed to maintain an infection prevention and control program for 5 of 5 residents reviewed for infection control. Residents #52, #53, #87, and #121 had orders for enhanced barrier precautions, but the report states the facility did not ensure those precautions were initiated. For Resident #52, the record showed an order for enhanced barrier precautions related to chronic wounds, MDRO colonization or infection, ostomy, IV therapy, dialysis, or indwelling devices, and the care plan reflected enhanced barrier precautions had been initiated; however, during observation the room had no posted signage indicating enhanced barrier precautions and no PPE cart was present in the hallway. Resident #52 was admitted after heart surgery and had a surgical wound on the chest and a wound on the right thigh. Resident #53 had diagnoses including sepsis and UTI, with an order for enhanced barrier precautions, but the care plan did not reflect enhanced barrier precautions and the room also lacked signage and a PPE cart. Resident #87 had diagnoses including surgical aftercare following circulatory system surgery and dependence on renal dialysis, with an order and care plan for enhanced barrier precautions, but the room likewise had no signage and no PPE cart. Resident #121 had an order for enhanced barrier precautions, and the room was observed without signage and without a PPE cart. The facility also failed to ensure contact isolation precautions were initiated for Resident #108 when she was admitted on antibiotic therapy for blood culture results positive for VRE. The DON stated she was unaware of Resident #108's VRE diagnosis and said Resident #108 should have been on contact isolation precautions based on that diagnosis. The DON also stated she was unaware of the missing transmission-based precaution signage and PPE carts for Residents #52, #53, #87, and #121, and said the signage and PPE carts should have been implemented as soon as staff became aware of the need for transmission-based precautions. The facility policy titled Infection Control Policy stated the resident's clinical record and door will display the appropriate isolation notification and that PPE should be readily available near the entrance to the resident's room.

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0880 citations
Failure to Use EBP, Perform Hand Hygiene, and Maintain Sanitary Laundry Practices
E
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

A resident with an indwelling Foley catheter had EBP identified in the care plan, but staff did not consistently wear gowns during close contact care, including vital signs, medication administration, hygiene-related contact, and topical treatment. In addition, a TMA administered medications to three residents without sanitizing hands between residents or before handling medications, despite policy and DON expectations requiring hand hygiene. Laundry practices were also inconsistent with sanitary handling, as staff sorted soiled laundry without gowns and gloves being available in the room and reported using only gloves for most dirty laundry tasks.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Infection Control Lapses During Insulin Administration
D
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

An LVN failed to follow hand hygiene and insulin pen preparation practices during a medication pass for a resident with diabetes. After washing his hands, he turned off the faucet with his bare hand, then administered insulin without cleaning the insulin pen’s rubber seal with alcohol first. The DON stated both actions were a break in infection control, and the facility policy required proper hand hygiene and noted that gloves do not replace hand hygiene.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Perform Hand Hygiene During Wound Care
D
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

Failure to perform hand hygiene during wound care was identified for a resident with a stage 4 coccyx pressure ulcer, diabetes, CAD, and HTN. An RN and the ADON provided perineal and wound care, but the RN repeatedly changed gloves without sanitizing hands and did not sanitize hands or change gloves before removing soiled packing and applying new wound packing and a dressing. The DON stated staff were expected to sanitize hands every time gloves were removed, and facility policy required hand hygiene after glove removal and before moving from a contaminated body site to a clean body site.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Infection Control Failures During Medication Pass and Respiratory Equipment Storage
D
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

An RN failed to follow hand hygiene and safe medication handling during med pass, including touching dropped tablets and handling meds without gloves or hand hygiene between steps. The facility also failed to store nebulizer mouthpieces and masks in labeled bags when not in use for residents receiving respiratory treatments, including a resident with CHF, CKD, DM2, and anemia. The DON confirmed the expected storage and handling practices were not followed.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Improper Cleaning of Community-Use Glucometer
E
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

An LPN was observed cleaning a community-use glucometer with an alcohol pad instead of the bleach wipe or equivalent required by the facility policy. The LPN stated he always used alcohol pads, while the DNS stated staff were to use bleach wipes. The glucometer was used for CBG checks on several residents with diabetes, and their records did not indicate a BBP.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Use PPE During Wound Care and Replace Oxygen Tubing Timely
E
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

A resident with MRSA and an abdominal wound was observed during wound care with contracted wound care staff entering without proper PPE, touching room items, and performing wound care without consistent hand hygiene or glove changes while moving from dirty to clean tasks; the same staff then went to another resident’s room without gowns despite EBP signage. The facility also failed to timely replace another resident’s oxygen tubing for CPAP/oxygen use, and the tubing had no label showing when it was last changed.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Citation search

Search every citation & Plan of Correction

Go to search
Citation watch

Track new serious citations across Texas

Get a heads-up on the newest immediate-jeopardy (J–L) citations in Texas — where surveyors are focused right now.

Free · about one email a month

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release August 26, 2026) and official state health department websites — never guesswork.

In your survey window? See what surveyors are citing.

The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.

Get the Survey-Prep Report
An unhandled error has occurred. Reload 🗙

Connection lost — reconnecting… We couldn't reconnect automatically. Please reload the page to continue.