Medication Error Rate Exceeded 5 Percent
Summary
The facility failed to ensure its medication error rate remained below five percent. Surveyors determined a 23 percent medication error rate based on 38 medication opportunities with nine medication errors, involving Residents 13 and 17. The errors were identified through observation of medication administration, clinical record review, and interviews with staff and residents. For Resident 17, the RN did not have artificial tears or Lidocaine patches available in the medication cart during the 9:00 AM medication pass. The RN also did not administer four scheduled medications: Pyridoxine HCL, Loratadine, Fluticasone Propionate nasal spray, and Fluticasone-Umeclidin-Vilant inhalation powder. The RN stated the electronic medication administration system automatically entered U-SA for Flonase because it was listed as self-administered and kept at the bedside, but the resident stated she did not take Flonase that morning and it was not in her room. The RN also found Ipratropium Bromide nasal spray in an unlocked drawer in the resident’s bedside stand, although there was no physician order for the resident to self-administer that medication. The DON later confirmed there was no evidence of an assessment showing the resident was capable of self-administration, and maintenance staff had supplied the resident a key to the lockable drawer after the observation. For Resident 13, the RN prepared and administered medications incorrectly during the morning pass. The resident received two tablets of Tylenol Arthritis instead of one, one tablet of Sodium Bicarbonate instead of two tablets to equal the ordered 650 mg dose, and five tablets of Ferrous Sulfate instead of one tablet. The RN also administered Amlodipine and Carvedilol without obtaining the required blood pressure assessment specified in the physician orders. The RN stated she believed five iron tablets were needed to equal 325 mg and acknowledged she did not review the bottle labeling showing the ordered tablet strength. The RN and the DON reviewed these medication errors with the surveyor.
Penalty
Resources
Below are regulatory guidelines relevant to this citation:
Trusted data from CMS and state health departments
Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release July 29, 2026) and official state health department websites — never guesswork.
In your survey window? See what surveyors are citing.
The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.