Failure to Monitor Dialysis Access and Keep Emergency Supplies Available
Summary
The facility failed to provide safe, appropriate dialysis care and services for a resident with chronic kidney disease stage 5 and dependence on renal dialysis. Resident #41 was cognitively intact and received hemodialysis. The resident had a right chest dialysis access site, but the physician’s order did not include directions to monitor or assess for complications and to document those assessments. The care plan included monitoring for infection, bleeding, hemorrhage, bacteremia, septic shock, and vital signs and weight per protocol, but the nursing progress notes from 8/2/25 through 8/26/25 did not show observation or care of the hemodialysis catheter or pre- and post-dialysis condition. On 8/27/25 at 7:30 A.M., the surveyor observed the dialysis access site to the right upper chest covered with undated bordered gauze, and the resident stated that nursing staff had not provided care to assess the site upon return from dialysis. The resident’s TAR and MAR for 8/26/25 did not indicate orders to monitor or assess the right chest port for complications. During interviews, nursing staff and the DON stated that dialysis residents should have site assessments, documentation, and communication with the dialysis center, and that complications could include bleeding, infection, dislodgement, inflammation, or redness. The DON also stated that the resident should have an emergency kit in the room and that gauze would be used for pressure if bleeding occurred. The facility also failed to ensure an emergency kit with clamps was kept with the resident for an emergency related to the tunneled hemodialysis catheter. On 8/26/25 and again on 8/27/25, the surveyor did not observe emergency clamps or pressure dressings in the resident’s room. The DON later observed an emergency kit in the resident’s top drawer containing gauze, but was unaware that a clamp should be included for a resident with a hemodialysis catheter. The facility policy stated that if there is major bleeding from the post-dialysis site, pressure should be applied, emergency services and the dialysis center contacted, and the clamps on the lumens verified as closed.
Penalty
Resources
Below are regulatory guidelines relevant to this citation:
Trusted data from CMS and state health departments
Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release October 8, 2026) and official state health department websites — never guesswork.
In your survey window? See what surveyors are citing.
The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.