F0759 F759: Ensure medication error rates are not 5 percent or greater.
E

Medication Administration Errors Exceeded 5 Percent

Dexter House HealthcareMalden, Massachusetts Survey Completed on 09-26-2025

Summary

The facility failed to ensure it was free from a medication error rate greater than 5%, with three nurses making four errors out of 25 observed medication administration opportunities for a 16% error rate. During observations and record review, Nurse #1 administered a standard multiple vitamin to Resident #70 even though the physician’s order was for one tablet of multiple vitamins with minerals, and she stated the correct product was not on her medication cart or available in the medication storage room. The DON stated nursing should have obtained the correct multiple vitamins. For Resident #46, Nurse #2 administered the incorrect form of aspirin by crushing and giving enteric coated aspirin when the order was for aspirin 81 mg chewable tablet, and she also crushed Carbidopa-Levodopa ER 50-200 mg despite the medication card stating, “HIGH ALERT, DO NOT CRUSH OR CHEW.” For Resident #34, Nurse #3 administered enoxaparin 40 mg intramuscularly into the right vastus lateralis muscle, holding the skin taut and injecting into the muscle, even though the physician’s order directed subcutaneous administration. Nurse #3 stated she should have given the injection subcutaneously into the abdomen, and the DON agreed that it should have been administered subcutaneously.

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0759 citations
Medication Error Rate Exceeded Due to Unprimed Insulin Pen Administration
D
F0759 F759: Ensure medication error rates are not 5 percent or greater.
Short Summary

Medication error rate exceeded the 5% threshold when an RN administered two insulin doses to a resident with DM without priming the Lantus and NovoLog pens before each injection. Surveyors observed the RN give the ordered subcutaneous doses without completing the manufacturer-required safety test, and the RN stated she believed priming was only needed before first use. The DON and consultant pharmacist confirmed the pens should be primed before each dose.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Medication Administration Errors Exceeded Allowed Rate
D
F0759 F759: Ensure medication error rates are not 5 percent or greater.
Short Summary

Medication administration errors exceeded the allowed rate when an MA gave late doses, administered a BP medication outside ordered parameters, and gave an incorrect dose of a PPI. One resident with metabolic encephalopathy, cognitive communication deficit, and HTN received Metoprolol late, and another resident with seizures, stroke, GERD, and HTN received Levetiracetam late, Lisinopril despite BP below the hold parameter, and Pantoprazole at 20 mg instead of the ordered 30 mg.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Medication Error Rate Exceeded 5 Percent
E
F0759 F759: Ensure medication error rates are not 5 percent or greater.
Short Summary

Medication Error Rate Exceeded 5 Percent: The facility had a 7.41% medication error rate after two errors were identified. A resident ordered acetaminophen and Refresh Tears received acetaminophen and artificial tears instead of the ordered eye drops, and the CMA reported giving the meds with the morning pass and not notifying an LN that they were late. The pharmacist confirmed the eye drops and artificial tears were not the same medication, and the regional RN stated meds should be given within one hour before or after the scheduled time.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Medication Administration Error Rate Exceeded
D
F0759 F759: Ensure medication error rates are not 5 percent or greater.
Short Summary

Medication Administration Error Rate Exceeded: The facility had a 7% medication error rate during observation. An LPN gave a resident sucralfate as a tablet with water instead of as a slurry 1 hour before meals, and an RN administered only one Senna Plus tablet instead of two while lidocaine patches were unavailable and on order. The resident involved in the sucralfate error had anxiety, depression, muscle weakness, and moderate cognitive impairment.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Medication Administration Errors Exceeded Allowed Rate
D
F0759 F759: Ensure medication error rates are not 5 percent or greater.
Short Summary

Medication administration errors exceeded the allowed rate when surveyors observed 4 errors in 27 opportunities. An LPN gave one resident's Keppra, Lexapro, and metformin late despite orders for 9 AM administration, and another LPN gave a resident's metoprolol without breakfast even though the order required it with breakfast. The DON confirmed the facility policy required medications to be given within one hour of the ordered time, and staff acknowledged the orders were not followed.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Late Administration of Scheduled Morning Medications
E
F0759 F759: Ensure medication error rates are not 5 percent or greater.
Short Summary

Late Administration of Scheduled Morning Medications: Surveyors found an 11.11% med error rate after an MA gave three residents their 6:30 a.m. meds well after the scheduled time. One resident with dementia and DM received metformin late and initially refused it, while two other residents with GERD or indigestion-related orders received Protonix or omeprazole late while one was sleeping and another was resting in bed. Interviews with the MA, RN, and DON confirmed late administration was considered a med error and should be reported to nursing.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Citation search

Search every citation & Plan of Correction

Go to search
Citation watch

Track new serious citations across Massachusetts

Get a heads-up on the newest immediate-jeopardy (J–L) citations in Massachusetts — where surveyors are focused right now.

Free · about one email a month

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release August 26, 2026) and official state health department websites — never guesswork.

In your survey window? See what surveyors are citing.

The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.

Get the Survey-Prep Report
An unhandled error has occurred. Reload 🗙

Connection lost — reconnecting… We couldn't reconnect automatically. Please reload the page to continue.