F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
D

Unlabeled enteral feeding bags

Brookdale RosehillShawnee, Kansas Survey Completed on 12-10-2025

Summary

The facility failed to ensure a resident’s tube feeding bags were labeled with the date, time, contents, and staff initials. The resident had diagnoses including myasthenia gravis, muscle weakness, COPD, and need for assistance with personal care. The admission MDS documented a BIMS score of 13, indicating intact cognition, and the MDS also noted supervision or touching assistance for eating. The feeding tube CAA documented that the resident received tube feeding three times a day after meals because the resident consumed less than 25 percent of meals. The resident’s care plan included enteral tube feeding interventions, site care, and checking tube placement before feeding and medication administration. The physician’s orders included nightly tube feeding and changing the enteral feeding bag and tubing, as well as a continuous enteral feed order. During observation, the resident’s enteral feeding bags were hanging next to the resident, with water in one bag and a brown-colored substance in the feeding line, and the bags were not dated with the content, date, time, or staff initials. A nurse stated the feeding bags should be labeled when hung, and an administrative nurse stated the bags should be labeled with the date, time, contents, and nurse’s initials.

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0693 citations
Unlabeled Tube Feeding Bags
D
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

A resident with a G-tube and diagnoses including stroke and pneumonitis had tube feeding ordered at 60 ml/hr, and the care plan identified increased nutritional risk related to gastric tube use. Staff observed the tube feeding bag hanging with an additional water bag, and both bags were not labeled with the resident’s name, formula, rate, date, or time hung; an RN and an LPN confirmed the unlabeled setup.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Feeding Tube Placement Not Verified Before Use
D
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

A resident with quadriplegia, dysphagia, and severe cognitive impairment had a G-tube used for meds, water flushes, and enteral nutrition. An LPN administered water, meds, and formula through the tube without checking placement or residual first, and the resident's care plan and MD orders did not include instructions to verify tube placement before use.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
GT Feeding Care Not Provided as Ordered
D
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

A resident with a GT, dysphagia, Parkinson's disease, and failure to thrive was observed lying flat in bed while receiving enteral feeding and water via pump, despite orders and care plan directions to keep the HOB elevated during feeding. The water bag connected to the pump was also not labeled with the resident's name, date, and time, and an LPN confirmed both the unlabeled bag and the resident's flat positioning during the feeding.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Tube Feeding Not Dated or Timed
D
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

A resident with dysphagia, severe cognitive impairment, and dependence on staff for ADLs received nocturnal Jevity 1.5 via feeding tube, but the bottle was not dated or timed when opened and the tubing was undated. During observation, the feeding was running on a pump while the resident rested in bed with the HOB elevated, and an LPN and the DON confirmed the dating and timing were missing.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Enteral Feeding Not Administered as Ordered
D
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

A resident who depended on PEG tube feeding was ordered Jevity 1.5 at 60 mL/hr for 22 hours daily with free-water flushes, but was observed disconnected from the feeding with the pump turned off and about 1,300 mL of formula still hanging at the bedside. An LPN confirmed she had not connected the feeding and said she forgot to do so, and the DON later confirmed the enteral feeding had not been connected as ordered.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Feeding Tube Pump Left Paused and Alarming
D
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

A resident with dysphagia, protein-calorie malnutrition, and dementia had a GT feeding ordered to run 20 hours daily via pump. During observation, the pump was found inactive, paused, and alarming with feeding still remaining in the bottle, and an LVN said she was unaware of the alarm or why the pump was paused. The DON stated tube feedings may be paused for care or meds but should be restarted as soon as possible so the resident receives the full ordered dose.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Citation search

Search every citation & Plan of Correction

Go to search
Citation watch

Track new serious citations across Kansas

Get a heads-up on the newest immediate-jeopardy (J–L) citations in Kansas — where surveyors are focused right now.

Free · about one email a month

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release October 8, 2026) and official state health department websites — never guesswork.

In your survey window? See what surveyors are citing.

The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.

Get the Survey-Prep Report
An unhandled error has occurred. Reload 🗙

Connection lost — reconnecting… We couldn't reconnect automatically. Please reload the page to continue.