Inappropriate AED Use on a Conscious Resident
Summary
The facility failed to ensure that nursing staff had the appropriate competencies and skill sets to provide nursing interventions, including the use of an AED and administering a shock on a conscious, breathing resident. The deficiency involved one resident who had severe cognitive impairment and diagnoses including CAD, HF, dementia, COPD, anxiety, depression, and schizophrenia, and who also had shortness of breath when lying flat and was receiving antipsychotic, antidepressant, and anticoagulant medications. The resident developed a change in condition with fever, altered mental status, abnormal vital signs, shortness of breath, hypotension, tachycardia, and low oxygen saturation. Nursing documentation described worsening findings, including a pulse reported as high as 250 beats per minute and oxygen saturation in the 70s on room air. The nurse documented inability to auscultate an apical pulse or palpate a radial pulse, and an AED was applied. The AED advised a shock, and one shock was delivered even though the resident was conscious and breathing. After the shock, the nurse documented that the resident’s tremors slowed, breathing returned to normal, pulse and oxygen saturation improved, and the resident became more alert. Hospital and EMS records stated the resident was not reported to be pulseless or unresponsive and was awake and alert on scene. The ED physician documented that EMS reported the nursing home connected an AED to the resident and shocked him even though he was reportedly not unconscious. The resident was noted to have generalized intermittent shaking and tremors, and he reported that he always shakes. Interviews with staff showed that the nurse used the AED because she believed it would detect whether the resident needed a shock, despite the resident being responsive. The facility’s AED guide and policy stated the AED is for use when a victim is unconscious, not breathing normally, and has no pulse or signs of circulation, and that it should not be used when a patient is conscious, breathing, or has a detectable pulse.
Penalty
Resources
Below are regulatory guidelines relevant to this citation:
Trusted data from CMS and state health departments
Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release July 29, 2026) and official state health department websites — never guesswork.
In your survey window? See what surveyors are citing.
The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.