F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
D

GT Feeding Orders Not Followed and HOB Not Elevated During Tube Feedings

Pelican Ridge Post AcuteNewport Beach, California Survey Completed on 08-19-2025

Summary

The facility failed to provide appropriate care and services for residents with gastrostomy tubes for three sampled residents. For one resident with no capacity to understand and make decisions, the physician ordered continuous enteral feeding with Nepro at 40 ml per hour for 20 hours and intermittent water flushes at 30 ml per hour for 20 hours. During observation, the resident was receiving the feeding at the ordered rate, but the water flush was running at 25 ml per hour. On a later observation, the Kangaroo pump was turned off even though residual feeding remained, and the LVN verified the resident had not completed the ordered feeding volume and still needed 242 ml to finish it. The DON acknowledged that the enteral feeding needed to continue after 1000 hours until the ordered volume was completed. For a second resident with dysphagia and no capacity to understand and make decisions, the care plan directed staff to elevate the HOB at least 30 to 45 degrees during and 30 minutes after tube feedings. The physician ordered continuous Jevity 1.5 at 60 ml per hour for 20 hours. During observation while the resident was receiving the feeding, the HOB was not elevated between 30 and 45 degrees and was measured at 20 degrees. The LVN confirmed the HOB was at 20 degrees and stated it should have been elevated at least 30 to 45 degrees while the feeding was infusing to prevent aspiration. For a third resident with fluctuating capacity who could make needs known, the care plan for enteral feeding also directed HOB elevation of at least 30 to 45 degrees during and 30 minutes after tube feedings. The physician ordered continuous Glucerna 1.2 at 75 ml per hour from 1400 hours to 1000 hours. During observation, the resident was lying in bed receiving the feeding with the HOB at less than 30 degrees and measured at 20 degrees. A CNA verified the HOB was at 20 degrees while the feeding was infusing, and an RN stated the HOB should be elevated to 30 to 45 degrees during enteral feeding. The DON acknowledged the findings.

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0693 citations
Incomplete Enteral Feeding Order for Resident with G-Tube
D
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

A resident with a g-tube, dysphagia, and malnutrition had an enteral feeding order that omitted the formula strength and the administration method. The chart showed the resident was receiving Isosource 1.5 cal bolus feedings, but the active order only stated enteral feed via g-tube. The MDS Coordinator, LVN, and DON all acknowledged the order was incomplete, and the facility policy required enteral nutrition orders to include the product and administration method.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Verify GT Placement Before Medication Administration
D
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

A resident with a GT, GERD, interstitial pulmonary disease, and dementia was observed receiving medications via the GT without the nurse confirming tube placement. The LVN stated she did not check GRV before administering the medications, and the RN and DON stated GT placement and residuals should be checked prior to medication administration, although the facility policy did not include GRV checking.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Inadequate G-tube care and enteral feeding documentation
E
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

Inadequate G-tube care and enteral feeding documentation. A resident with CVA-related hemiplegia and dysphagia had orders for NPO status, continuous Jevity 1.5 via G-tube, water flushes, residual checks every shift, and oral care, but the record lacked an order for tube placement verification or shift site care. MAR/TAR review showed no consistent documentation of G-tube site care or residual checks, water flushes were not always documented as ordered, and feeding amounts were recorded in two places with inconsistent entries; nursing notes were also not present for every shift.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Delayed G-tube Feeding Administration
D
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

A resident with a g-tube, severe cognitive impairment, and dependence on staff for all nutrition and hydration did not receive continuous tube feeding at the ordered start time. The feeding pump was observed off while the resident was away from his room and remained off after he returned from the Day Center; an LVN later connected the feeding after changing the g-tube dressing. Staff stated the resident often returned after the ordered start time and was therefore not hooked up as ordered.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Resident with G-tube was fed while lying flat
D
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

A resident with a G-tube was observed lying supine and below 30 degrees while enteral feeding was running. A CNA said the resident was lower than she should have been during the feeding and that the tube feeding should be turned off when repositioning is needed. An LVN later confirmed the resident should not be lying flat during feeding, paused the tube feeding, and said the resident needed assistance to be safely elevated; the DON stated the head should be elevated above 30 to 45 degrees and never flat during feeding.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Verify G-Tube Placement Before Medications and Water Administration
D
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

Failure to Verify G-Tube Placement Before Medications and Water Administration: An LPN administered crushed meds and water through a resident’s PEG tube without routinely checking tube placement first. The resident had dysphagia, cognitive impairment, and received most calories and fluids via the feeding tube. The RN and DON also indicated uncertainty about whether placement checks were still required, and no provider order exempting the resident from placement verification was found, despite the facility policy requiring placement checks before tube feedings and meds.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Citation search

Search every citation & Plan of Correction

Go to search
Citation watch

Track new serious citations across California

Get a heads-up on the newest immediate-jeopardy (J–L) citations in California — where surveyors are focused right now.

Free · about one email a month

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release August 26, 2026) and official state health department websites — never guesswork.

In your survey window? See what surveyors are citing.

The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.

Get the Survey-Prep Report
An unhandled error has occurred. Reload 🗙

Connection lost — reconnecting… We couldn't reconnect automatically. Please reload the page to continue.