Insulin Pen Not Primed According to Manufacturer Instructions
Summary
The facility failed to ensure that an insulin pen was prepared and administered according to the manufacturer's instructions for one resident who was observed receiving insulin. During the 8:06 AM medication pass, RN #4 placed a needle on an Aspart FlexPen, dialed up 2 units, and while holding the pen horizontally depressed the plunger toward the medication cart, with no insulin observed exiting the pen. RN #4 then dialed up the resident’s sliding scale dose of 4 units plus the routine pre-meal dose of 10 units, for a total of 14 units, and administered the dose to the resident’s abdomen. After administration, RN #4 stated that priming was done to relieve air bubbles and confirmed that 2 units should be dialed up and ejected, but did not indicate that the pen should be held vertically or that a drop of insulin should be seen during priming. The resident had diagnoses including type 2 diabetes mellitus and a quarterly MDS showed a BIMS score of 08, indicating severe cognitive impairment. The resident’s orders included insulin aspart FlexPen by sliding scale before meals and at bedtime, as well as 10 units subcutaneously with meals before breakfast, with instructions to hold if CBG was less than 90 or the resident was not eating. A laboratory report dated 9/10/2025 showed an HbA1c of 9.1, which the APN described as elevated. The APN stated that medication administration staff are expected to administer physician-ordered medications correctly and follow facility policy, and explained that insulin pen priming should be done with the pen pointed up and held for a count of 5 or 6 seconds. The DON and Administrator both confirmed that medications must be administered according to physician orders and facility policy, and that failure to do so would be considered a medication error. The facility policy required medications to be administered as prescribed and according to the rights of medication administration, and the manufacturer’s instructions stated that the pen should be held with the needle pointing up during priming until a drop of insulin is observed.
Penalty
Resources
Below are regulatory guidelines relevant to this citation:
Trusted data from CMS and state health departments
Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release October 8, 2026) and official state health department websites — never guesswork.
In your survey window? See what surveyors are citing.
The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.